HP StorageWorks 2/32 Brocade Fabric OS Documentation Addendum - Supporting Fab - Page 80
AG-1012, AG-1013, AG-1014
View all HP StorageWorks 2/32 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 80 highlights
2 AG-1012 AG-1012 Message , [AG-1012], ,, WARNING, , FDISC sent from N-Port failed Probable Cause Recommended Action Severity Indicates that the N_Port logout request sent to the fabric switch from the Access Gateway failed. Verify the configuration of the fabric switch. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING AG-1013 Message , [AG-1013], ,, INFO, , Failing over all F_Ports mapped to N_Port to other N_Port(s) Probable Indicates that the F_Ports were failed over to another N_Port(s) that is connected to the same fabric. Cause Recommended Run the ag --mapshow command to display the updated F-Port to N-Port mapping. Action Severity INFO AG-1014 Message , [AG-1014], ,, INFO, , Failing back F_Ports to mapped to N_Port Probable Indicates that the N_Port is back online and the F_Ports have been failed back to the N_Ports to which Cause they were mapped. Recommended Run the ag --mapshow command to display the updated F-Port to N-Port mapping. Action Severity INFO 2-6 Fabric OS Documentation Addendum Publication Number: 53-1000429-01-HP