HP StorageWorks 8/80 HP StorageWorks Fabric OS 6.1.0h release notes (5697-7961 - Page 19

Solution, Closed defect summary, Brocade 4-Gb SAN Switch for HP c-Class BladeSystem power-on-self - san switch specifications

Page 19 highlights

Closed defect summary Solution An "ipfilter --transabort" command running in one Telnet session can be aborted from another Telnet session. Fixed in Fabric OS 6.1.0 Cannot set "Portlog events enable" accurately. Fixed in Fabric OS 6.1.0 The DC Director may ASSERT in a specific test scenario while running Fixed in Fabric OS 6.1.0 a particular FICON test program (SAK IRNDUP). Brocade 4-Gb SAN Switch for HP c-Class BladeSystem power-on-self- Fixed in Fabric OS 6.1.0 test (POST) failure on chassis power on. Flooding of an unknown inter-switch FDMI command from another vendor's switch is causing the switch to crash. Fixed in Fabric OS 6.1.0 DC Director port blades are re-initialized during supportsave. Fixed in Fabric OS 6.1.0 2-Gb Channels fail to come online from T-Rexx mainframe to a 128- Fixed in Fabric OS 6.1.0 port 4/256 SAN Director. Occasional kernel panic during reboot in AG setup. Fixed in Fabric OS 6.1.0 Under very rare conditions, and in a configuration where there are multiple paths configured to reach multiple devices, some paths were observed not coming online. Fixed in Fabric OS 6.1.0 During fastwrite, a 3rd party device drops a status frame due to Fixed in Fabric OS 6.1.0 data alignment. HaFailover not working after upgrading firmware from Fabric OS Fixed in Fabric OS 6.1.0 5.0 to 5.2.0a using firmrwaredownload -s on each CP. Heart beat missing being reported by CP - Standby CP reboots. Fixed in Fabric OS 6.1.0 FICON Virtual Tape Pipelining does not function correctly with specific Fixed in Fabric OS 6.1.0 tape devices. Blade fault does not result in LIRR and async status. Fixed in Fabric OS 6.1.0 Firmware upgrade on 4/8 SAN Switch and 4/16 SAN Switch to Fabric OS 6.0.0 will cause the switch to report marginal state. Fixed in Fabric OS 6.1.0 CUP Set Offline inline command not presenting status before going Fixed in Fabric OS 6.1.0 offline. Usability: Ctrl-C in legacy configdownload code is not blocked during downloads. Fixed in Fabric OS 6.1.0 Switch faults if Management Server Domain is invalid, limited commands available. Fixed in Fabric OS 6.1.0 When a switch's IDID mode is currently OFF and we disable the switch, Fixed in Fabric OS 6.1.0 the rest of the switches in the fabric get a premature duplicate message. Async error reporting events are lost if detected immediately after switch boot. Fixed in Fabric OS 6.1.0 Fabric Manager: Configdownload actually downloads all the disruptive parameters in the Validation step in Fabric Manager, when the switch is in a disabled state. Fixed in Fabric OS 6.1.0 HP StorageWorks Fabric OS 6.1.0h release notes 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30

Solution
Closed defect summary
Fixed in Fabric OS 6.1.0
An "
ipfilter --transabort
" command running in one Telnet
session can be aborted from another Telnet session.
Fixed in Fabric OS 6.1.0
Cannot set "
Portlog events enable
" accurately.
Fixed in Fabric OS 6.1.0
The DC Director may ASSERT in a specific test scenario while running
a particular FICON test program (SAK IRNDUP).
Fixed in Fabric OS 6.1.0
Brocade 4-Gb SAN Switch for HP c-Class BladeSystem power-on-self-
test (POST) failure on chassis power on.
Fixed in Fabric OS 6.1.0
Flooding of an unknown inter-switch FDMI command from another
vendor's switch is causing the switch to crash.
Fixed in Fabric OS 6.1.0
DC Director port blades are re-initialized during
supportsave
.
Fixed in Fabric OS 6.1.0
2-Gb Channels fail to come online from T-Rexx mainframe to a 128-
port 4/256 SAN Director.
Fixed in Fabric OS 6.1.0
Occasional kernel panic during reboot in AG setup.
Fixed in Fabric OS 6.1.0
Under very rare conditions, and in a configuration where there are
multiple paths configured to reach multiple devices, some paths were
observed not coming online.
Fixed in Fabric OS 6.1.0
During
fastwrite
, a 3rd party device drops a status frame due to
data alignment.
Fixed in Fabric OS 6.1.0
HaFailover
not working after upgrading firmware from Fabric OS
5.0 to 5.2.0a using
firmrwaredownload -s
on each CP.
Fixed in Fabric OS 6.1.0
Heart beat missing being reported by CP - Standby CP reboots.
Fixed in Fabric OS 6.1.0
FICON Virtual Tape Pipelining does not function correctly with specific
tape devices.
Fixed in Fabric OS 6.1.0
Blade fault does not result in LIRR and async status.
Fixed in Fabric OS 6.1.0
Firmware upgrade on 4/8 SAN Switch and 4/16 SAN Switch to
Fabric OS 6.0.0 will cause the switch to report
marginal
state.
Fixed in Fabric OS 6.1.0
CUP Set Offline
inline
command not presenting status before going
offline.
Fixed in Fabric OS 6.1.0
Usability:
Ctrl-C
in legacy
configdownload
code is not blocked
during downloads.
Fixed in Fabric OS 6.1.0
Switch faults if Management Server Domain is invalid, limited com-
mands available.
Fixed in Fabric OS 6.1.0
When a switch's IDID mode is currently OFF and we disable the switch,
the rest of the switches in the fabric get a premature duplicate message.
Fixed in Fabric OS 6.1.0
Async error reporting events are lost if detected immediately after
switch boot.
Fixed in Fabric OS 6.1.0
Fabric Manager:
Configdownload
actually downloads all the dis-
ruptive parameters in the Validation step in Fabric Manager, when
the switch is in a disabled state.
HP StorageWorks Fabric OS 6.1.0h release notes
19