HP StorageWorks 8/80 HP StorageWorks Fabric OS 6.1.0h release notes (5697-7961 - Page 24

Fabric OS 6.1.0b fixes, lists defects closed in the Fabric OS 6.1.0b firmware release.

Page 24 highlights

Fabric OS 6.1.0b fixes Table 8 lists defects closed in the Fabric OS 6.1.0b firmware release. Table 8 Fabric OS 6.1.0b closed defects Closed defect summary Solution I2C response failure and subsequent reset will occasionally result in DC Director fan fault errors. Fixed in Fabric OS 6.1.0b When running stressful SAK IRNDUP to CUP tests, user may observe Fixed in Fabric OS 6.1.0b Intermittent Channel Timeouts. In a FICON Extender environment in which a host path goes offline, Fixed in Fabric OS 6.1.0b the switch does not link time-out the F_Port. HP StorageWorks 400 Multi-protocol Router: If there are multiple Initi- Fixed in Fabric OS 6.1.0b ators fanned into a single FCIP fastwrite tape target, the tape may be marked prematurely as full. When physically replacing an N_Port device with an ISL in a soft zone Fixed in Fabric OS 6.1.0b configuration, a DC SAN Director panic occurs. Traffic Isolation failover policy reverts back to "disabled" from "enabled" after changing the port membership list. Fixed in Fabric OS 6.1.0b Potential timeouts and aborts during Device Discovery and CU busy processing when using FICON XRC Emulation. Fixed in Fabric OS 6.1.0b Integrated Routing with multiple ports in an Ex_Port trunk, may not properly send an entire exchange on the same link. Fixed in Fabric OS 6.1.0b FICON CUP reports incorrect Director Size Code in Basic Sense and Fixed in Fabric OS 6.1.0b Sense ID data for HP StorageWorks 8/40 and 8/80 SAN Switches. FICON Channel continuously sends RRQ frames for approximately 20 Fixed in Fabric OS 6.1.0b seconds before aborting. If QoS and Diff Serv are enabled, some FCIP tunnels may not come online in the case of an 8 to 1 fan-in scenario. Fixed in Fabric OS 6.1.0b When the proxy device projected to the backbone has a translate Fixed in Fabric OS 6.1.0b domain of greater than 0x20, the router is not properly translating the ACC for a REC. Traffic is interrupted and the tape device fails. HP StorageWorks 8/80 SAN Switch fan module can be marked faulty Fixed in Fabric OS 6.1.0b after multiple and repeated removals/reinsertions. 24

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30

Fabric OS 6.1.0b fixes
Table 8
lists defects closed in the Fabric OS 6.1.0b firmware release.
Table 8 Fabric OS 6.1.0b closed defects
Solution
Closed defect summary
Fixed in Fabric OS 6.1.0b
I2C response failure and subsequent reset will occasionally result in
DC Director fan fault errors.
Fixed in Fabric OS 6.1.0b
When running stressful SAK IRNDUP to CUP tests, user may observe
Intermittent Channel Timeouts.
Fixed in Fabric OS 6.1.0b
In a FICON Extender environment in which a host path goes offline,
the switch does not link time-out the F_Port.
Fixed in Fabric OS 6.1.0b
HP StorageWorks 400 Multi-protocol Router: If there are multiple Initi-
ators fanned into a single FCIP fastwrite tape target, the tape may be
marked prematurely as full.
Fixed in Fabric OS 6.1.0b
When physically replacing an N_Port device with an ISL in a soft zone
configuration, a DC SAN Director panic occurs.
Fixed in Fabric OS 6.1.0b
Traffic Isolation failover policy reverts back to "disabled" from "en-
abled" after changing the port membership list.
Fixed in Fabric OS 6.1.0b
Potential timeouts and aborts during Device Discovery and CU busy
processing when using FICON XRC Emulation.
Fixed in Fabric OS 6.1.0b
Integrated Routing with multiple ports in an Ex_Port trunk, may not
properly send an entire exchange on the same link.
Fixed in Fabric OS 6.1.0b
FICON CUP reports incorrect Director Size Code in Basic Sense and
Sense ID data for HP StorageWorks 8/40 and 8/80 SAN Switches.
Fixed in Fabric OS 6.1.0b
FICON Channel continuously sends RRQ frames for approximately 20
seconds before aborting.
Fixed in Fabric OS 6.1.0b
If QoS and Diff Serv are enabled, some FCIP tunnels may not come
online in the case of an 8 to 1 fan-in scenario.
Fixed in Fabric OS 6.1.0b
When the proxy device projected to the backbone has a translate
domain of greater than 0x20, the router is not properly translating the
ACC for a REC. Traffic is interrupted and the tape device fails.
Fixed in Fabric OS 6.1.0b
HP StorageWorks 8/80 SAN Switch fan module can be marked faulty
after multiple and repeated removals/reinsertions.
24