HP Surestore E Disk Array XP256 HP XP P9000 External Storage Access Manager Us - Page 73
Troubleshooting suspended pairs when using RAID Manager
View all HP Surestore E Disk Array XP256 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 73 highlights
Suspend type VOL Type PSUE, P-VOL S-VOL Failure S-VOL PSUE, MCU IMPL P-VOL S-VOL PSUE, Initial Copy Failed P-VOL S-VOL Error Corrective action resynchronize the pair from the MCU (Pairresync). • Because of the quorum disk failure, the multipath software will show that the S-VOL is offline. Resynchronize the pair as described above, and then make the path to the S-VOL online with the multipath software. The settings for host mode option 52 differ between ports on the primary and secondary storage systems. Do one of the following: • If you do not use cluster systems, disable host mode option 52. • If you use cluster systems, enable host mode option 52 for host groups where an executing node and a standby node belong. The primary storage system could not Resynchronize the pair. This results in an find valid control information in its initial copy operation. nonvolatile memory during IMPL. This condition only occurs if the primary storage system is without power for more than 48 hours (for example, a power failure and fully discharged backup batteries). The pair was suspended before the initial copy completed. Data on the S-VOL is not identical to data on the P-VOL. Do the following: • Release the pair from the primary storage system. • Clear all error conditions at the primary storage system, P-VOL, secondary storage system, and S-VOL. • Restart the initial copy operation. Troubleshooting suspended pairs when using RAID Manager The basic steps involved in resolving suspended volume pairs when using RAID Manager include: • Using the RAID Manager operation log file to identify the cause of the error. • Following the troubleshooting steps based on the SSB1 and SSB2 error codes (the codes are recorded in the log file). Location of the RAID Manager operation log file The file is stored in the following directory by default: /HORCM/log*/curlog/horcmlog_HOST/horcm.log. Where: • * is the instance number. • HOST is the host name. Error codes appear on the right of the equal symbol (=). Example log file Two error codes are included in this example (B9E1 and B901). Suspended volume pair troubleshooting 73