Honeywell HW2000i Owners Manual - Page 26
to remove any dirt and debris., Remove the oil drain pipe. - generator inverter
UPC - 894190002193
View all Honeywell HW2000i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
Engine Oil Engine Oil 6. Place the oil pan, or other container suitable for holding engine oil, in front of the generator. FIGURE 23: Oil Drain Pan 7. Remove the oil fill cap. CAUTION Generator is heavy! Obtain assistance to lift the generator to avoid back or other bodily injury. 9. Return the unit to the upright position. 10. Remove the oil drain pipe. 11. Using a clean cloth, wipe around the drain plug area to remove any dirt and debris. 12. Fill the oil fill container (included) with the appropriate amount and type of new (unused) oil. (See Figure 17 for recommended oil type.) HW1000i Oil Capacity [qt / ml] 0.26 / 250 TABLE 5. Engine Oil Capacity HW2000i 0.48 / 450 13. Slowly pour oil into the oil fill hole. DO NOT OVERFILL. FIGURE 26: Adding Engine Oil 14. Check the oil level is up to the innermost thread of the crankcase. FIGURE 24: Oil Fill Cap Removal 8. Attach the oil drain pipe (do not over tighten) and tilt the generator allowing the oil to completely drain into the oil pan. FIGURE 25: Drain Oil (HW2000i Model) 20 www.honeywellgenerators.com FIGURE 27: Oil Fill Measurement HW1000i / HW2000i Inverter Generator Owner's Manual