    Non-programmable Thermostat INSTALLATION INSTRUCTIONS The RTH5100B Thermostat provides electronic control of 24 Vac singlestage heating and cooling systems or 750 mV heating systems. START HERE For assistance with your Honeywell product, please visit www.honeywell.com/yourhome or call Honeywell
  • Honeywell RTH5100B | Owner's Manual - Page 2
    for Installation 3 Follow Important Instructions 5 Remove Old Thermostat 6 Follow Special Instructions 7 Label Old Thermostat Wires 10 Mount New Wallplate to Wall 11 Connect Wires to New Wallplate 15 Install Batteries 20 Attach New Thermostat to Wallplate 21 Configure Installer Setup 22
  • Honeywell RTH5100B | Owner's Manual - Page 3
    (2) OPERATING INSTRUCTIONS INSTALLATION INSTRUCTIONS WIRE LABELS OPERATING INSTRUCTIONS CAUTION CARD INSTA ATION CAUTION les X2 Y www M22033 If any of the items shown above are missing, call Honeywell Customer Care at 1-800-468-1502 before returning the thermostat to the store. 3 69
  • Honeywell RTH5100B | Owner's Manual - Page 4
    (Cont) 2. Check that you have everything required for the installation: • Two AAA alkaline batteries • No. 2 Phillips screwdriver and standard pocket screwdriver • Drill • Drill bit- use 3/16 in. for drywall; use 7/32 in. for plaster • Level (optional) • Hammer • Pencil • Electrical
  • Honeywell RTH5100B | Owner's Manual - Page 5
    to the heating and/or cooling system. These Installation Instructions explain later how to use the enclosed wire labels to correctly mark the wires connected to your old thermostat. OLD THERMOSTAT YELLOW WHITE Y W RED G GREEN RC R ORANGE ! DO NOT WIRE NEW THERMOSTAT BASED ON WIRE COLOR
  • Honeywell RTH5100B | Owner's Manual - Page 6
    Remove Old Thermostat 1. Turn off power at the heating and/or cooling system or fuse/circuit breaker panel. 2. Remove the cover from the old thermostat. 3. Remove the old thermostat from the wall or wallplate. Do not remove the wires. Y G C OLD THERMOSTAT WALLPLATE W THERMOSTAT R COVER .2.18
  • Honeywell RTH5100B | Owner's Manual - Page 7
    Special Instructions 1. If you have C and/or C1 wire(s) connected to your old thermostat, do not connect them to your new thermostat. 2. Disconnect the C and/or C1 wire(s). Make sure they do not touch each other or any other wires. 3. Wrap the bare end of each C and/or C1 wire(s) with electrical
  • Honeywell RTH5100B | Owner's Manual - Page 8
    Special Instructions (Cont) 4. Most installations have two to five wires connected to the old thermostat. If six or more wires are connected to your old thermostat (not counting the C or C1 wires), do not continue the installation. You may have purchased the wrong thermostat. Visit www.honeywell.com
  • Honeywell RTH5100B | Owner's Manual - Page 9
    Special Instructions (Cont) 5. If you find any wires not connected to your old thermostat, do not connect them to your new thermostat. 6. Wrap the end of the wires that are not connected with electrical tape. OLD THERMOSTAT Y G RC W R LETTER DESIGNATION SCREW TERMINAL WIRE WIRE HOLE WIRES NOT
  • Honeywell RTH5100B | Owner's Manual - Page 10
    remaining parts of the old thermostat from the wall. OLD THERMOSTAT W Y RC G Y G RC W R R WIRE LABEL LETTER DESIGNATION SCREW TERMINAL WIRE WIRE HOLE M22039 When connecting the wires to the new thermostat, refer to the wire labels. Do not connect wires to your new thermostat based on the color
  • Honeywell RTH5100B | Owner's Manual - Page 11
    Step 6. Mount New Wallplate to Wall 1. Separate the wallplate from the thermostat as shown. THERMOSTAT WALLPLATE WIRE HOLE M22042 11 69-1716
  • Honeywell RTH5100B | Owner's Manual - Page 12
    Step 6. Mount New Wallplate to Wall (Cont) 2. Pass the labeled wires through the wire hole on the wallplate. WALL OPENING WALLPLATE WIRE HOLE RC R Y NOT USED (O/B) W G LABELED WIRES 69-1716 12 M22043
  • Honeywell RTH5100B | Owner's Manual - Page 13
    the wallplate on the wall with the arrow pointing up. Level the wallplate (for appearance only) and mark the two mounting holes with a pencil. LEVEL RC R Y NOT USED (O/B) W G WALLPLATE PLACE LEVEL ON TABS MARK MOUNTING HOLES (2) M22044 13 69-1716
  • Honeywell RTH5100B | Owner's Manual - Page 14
    for plaster. 5. Tap the wall anchors into the drilled holes until even with the wall surface. DRILLED HOLES (2) WALL ANCHORS (2) WALLPLATE RC R Y NOT USED (O/B) W G MOUNTING SCREWS (2) M22046 6. Position the wallplate over the wall anchors. 7. Insert the mounting screws into the wall anchors
  • Honeywell RTH5100B | Owner's Manual - Page 15
    to the letter designations on the wallplate. 2. If wires are to be connected to both Rc and R, loosen the Rc and R screw terminals and remove the metal jumper. 3. If only one of the terminals, Rc or R, is to be connected, leave metal jumper in place. METAL JUMPER TERMINAL BLOCK SCREW TERMINALS
  • Honeywell RTH5100B | Owner's Manual - Page 16
    screw terminals. 5. If any of the labeled wires do not match the letter designations, see next page for wire connections. LABELED WIRES TERMINAL BLOCK SCREW TERMINALS LETTER DESIGNATIONS RC R Y NOT USED O/B W G GW Y R RC WALLPLATE RC R Y W/O/B G WIRE HOLE INSERT WIRE IN HOLE M22176 69-1716 16
  • Honeywell RTH5100B | Owner's Manual - Page 17
    to New Wallplate (Cont) 6. Compare letter designations on your old and new thermostats. New Possible letter designations Thermostat on the labeled wires 1 RC 2 RC or R 2 1 R or RH, 4, V R Y or Y1, M Y NOT USED O/B W 3 W or W1, H, O, B G or F G Do Not Connect C or X, B 4 M22055 Do
  • Honeywell RTH5100B | Owner's Manual - Page 18
    and RH terminals on the old thermostat, remove metal jumper between RC and R on the new thermostat. Connect the old R to the new RC and the old RH to the new R. 3 Do not connect both O and B when wiring to a heat pump. Connect O to O/B W. Wrap the bare end of the B wire with electrical tape and do
  • Honeywell RTH5100B | Owner's Manual - Page 19
    Step 7. Connect Wires to New Wallplate (Cont) 7. Push excess wire back into the wall opening. Keep wires in the shaded area. WALLPLATE RC R Y NOT USED (O/B) W G WIRE WALL OPENING SHADED AREA M22054 19 69-1716
  • Honeywell RTH5100B | Owner's Manual - Page 20
    Step 8. Install Batteries 1. Install two fresh AAA alkaline batteries on the back of the thermostat as marked on the battery holder. BACK OF THERMOSTAT BATTERY HOLDER BATTERIES M22056 69-1716 After the thermostat is mounted on the wallplate, the thermostat does not require removal from the
  • Honeywell RTH5100B | Owner's Manual - Page 21
    of the thermostat. WALLPLATE TABS RC R Y NOT USED O/B W G TABS SLOTS ON BACK OF THERMOSTAT M22057 2. Push the thermostat straight onto the wallplate until it snaps into place. 3. Turn on the power at the heating and/or cooling system or fuse/circuit breaker panel. If the wires interfere with
  • Honeywell RTH5100B | Owner's Manual - Page 22
    system. Follow the steps in this section to set up your thermostat. 2. Enter the Installer Setup Menu by pressing and holding the Up and Fan buttons at the same time, for approximately five seconds, until the screen changes. Replace Batt Service Needed Cool On Fan System Auto Cool M22058
  • Honeywell RTH5100B | Owner's Manual - Page 23
    the Up or Down button to select your setting for Installer Setup Number 1 in the table below. 5. After you select your setting, press the Next button to go to the next Installer Setup Number. INSTALLER SETUP NUMBER Replace Batt Service Needed Done Next SETTING UP BUTTON DOWN BUTTON NEXT BUTTON
  • Honeywell RTH5100B | Owner's Manual - Page 24
    button to go the next Installer Setup Number. INSTALLER SETUP NUMBER SETTING Replace Batt Service Needed Done Next UP BUTTON DOWN BUTTON NEXT BUTTON 2 69-1716 Heat Pump Changeover Valve Use this setting if you connected a wire labeled O to O/B W terminal. Use this setting if you connected
  • Honeywell RTH5100B | Owner's Manual - Page 25
    to go to the next Installer Setup Number. INSTALLER SETUP NUMBER SETTING Replace Batt Service Needed Done Next UP BUTTON DOWN BUTTON NEXT BUTTON 3 Fan Heating system Control in controls fan in a call for heat. Heating Thermostat controls fan in a call for heat. M22061 25 69-1716
  • Honeywell RTH5100B | Owner's Manual - Page 26
    select your setting for Installer Setup Number 5 in table below. 14. After you select your setting, press the Next button to go to the next Installer Setup Number. INSTALLER SETUP NUMBER Replace Batt Service Needed Done Next SETTING UP BUTTON DOWN BUTTON NEXT BUTTON 5 Heating Cycle Rate 69
  • Honeywell RTH5100B | Owner's Manual - Page 27
    Done button to exit the Installer Setup and save your settings. 17. Congratulations! The installation of the thermostat is complete. Refer to the enclosed Operating Instructions (69-1722) for information on how to operate your new thermostat. INSTALLER SETUP NUMBER SETTING DONE BUTTON Done Next
  • Honeywell RTH5100B | Owner's Manual - Page 28
    assistance with your Honeywell product please visit www.honeywell.com/yourhome or call Honeywell Customer Care toll free at 1-800-468-1502. Before calling, please have the thermostat model number and date code available. MODEL NUMBER xxxxxxxx DATE CODE xxxxxx THERMOSTAT BATTERY HOLDER 69-1716
  • Honeywell RTH5100B | Owner's Manual - Page 29
    Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, Honeywell shall repair or replace it (at Honeywell's option) within a reasonable period of time. If the product is defective, (i) return it, with a bill of sale
  • Honeywell RTH5100B | Owner's Manual - Page 30
    Warranty (Cont) THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED state to state. If you have any questions concerning this warranty, please write Honeywell Customer Relations, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-468-1502.
  • Honeywell RTH5100B | Owner's Manual - Page 31
    31 69-1716
  • Honeywell RTH5100B | Owner's Manual - Page 32
    Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 69-1716 G.H. 5-04 www.honeywell.com/yourhome
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

INSTALLATION INSTRUCTIONS
fi U.S. Registered Trademark
' 2004 Honeywell International Inc.
All Rights Reserved ° Patents Pending
69-1716
RTH5100B
Non-programmable Thermostat
The RTH5100B Thermostat provides electronic control of 24 Vac single-
stage heating and cooling systems or 750 mV heating systems.
For assistance with your Honeywell product, please visit
www.honeywell.com/yourhome
or call Honeywell Customer Care
toll free at 1-800-468-1502.
Read and Save these Instructions
START HERE