Appendix

Page 16 highlights

Appendix CONVERTING DISHWASHER WITH FACTORY EQUIPPED POWER CORD TO A PERMANENT CONNECTION This procedure requires the conversion leads set aside in Step 1. • Make sure the power cord for the dishwasher is unplugged from the wall outlet. • Remove screw from junction box cover and remove cover if present. • Disconnect the three power cord conductors from the dishwasher harness. Figure BB • Remove and discard the power cord. • Connect the conversion harness (included with dishwasher) to the dishwasher harness by connecting like-colored wires. Figure CC • Return to Step 16 in these instructions to complete the conversion. Figure BB Remove Strain Relief Disconnect Powercord Figure CC Conversion Harness 06H-1949_Conversion Harness SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE GE Consumer & Industrial ��GL�oeun�iesvr�ai�llleE�,lKe�ce�tnr�ticu�cCko�y�m4p�0a�2�n2y5��� ge.com 16 Pub. No. 31-30218 Dwg. No. 206C1559P158 ND 06H-1949 (10/06)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

GE Consumer & Industrial
General Electric Company
Louisville, Kentucky 40225
ge.com
Pub. No. 31-30218
Dwg. No. 206C1559P158
ND 06H-1949 (10/06)
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
Appendix
CONVERTING DISHWASHER WITH FACTORY
EQUIPPED POWER CORD TO A PERMANENT
CONNECTION
This procedure requires the conversion leads set
aside in Step 1.
• Make sure the power cord for the dishwasher is
unplugged from the wall outlet.
• Remove screw from junction box cover and
remove cover if present.
• Disconnect the three power cord conductors from
the dishwasher harness. Figure BB
• Remove and discard the power cord.
• Connect the conversion harness (included with
dishwasher) to the dishwasher harness by
connecting like-colored wires. Figure CC
• Return to Step 16 in these instructions to complete
the conversion.
Figure CC
Disconnect
Powercord
Remove
Strain Relief
Figure BB
Conversion Harness
16