Hotpoint HDA3500NWW Installation Instructions - Page 5
Installation Preparation-Electrical Supply - dishwasher model
UPC - 084691156185
View all Hotpoint HDA3500NWW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
Installation Preparation-Electrical Supply PREPARE ELECTRICAL WIRING WARNING FOR PERSONAL SAFETY: Remove house fuse or open circuit breaker before beginning installation. Do not use an extension cord or adapter plug with this appliance. Electrical Requirements • This appliance must be supplied with 120V, 60 Hz., a#n28d2cForennnchected to an individual properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse. • Wiring must be 2 wire with ground. • If the electrical supply does not meet the above requirements, call a licensed electrician before proceeding. Grounding Instructions-Permanent Connection This appliance must be connected to a grounded metal, permanent wiring system, or an equipment grounding conductor must be run with the circuit conductors and be connected to the equipment grounding terminal or lead on the appliance. Grounding Instructions-Power Cord Models This appliance must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an equipment grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is installed and grounded in accordance with all local codes and ordinances. WARNING The improper connection of the equipment grounding conductor can result in electric shock. Check with a qualified electrician or service representative if you are in doubt that the appliance is properly grounded. Do not modify the plug provided with the appliance; if it will not fit the outlet, have a proper outlet installed by a qualified technician. 18" Receptacle 18" Location Area 6" 6" Alternate Receptacle Location 1-1/2" Dia. Hole (Max.) 24" from Wall 3" from Cabinet Figure E Ground Black White Cabinet Preparation & Wire Routing • The wiring may enter the opening from either side, rear, or floor within the shaded area illustrated above in Figure E and defined in Figure A. 661Dia56A • Cut a 1-1/2" maximum diameter hole to insert the electrical cable. Permanent wiring connections may pass through the same hole as the drain hose and hot water line, if convenient. Hole edges must be smooth and rounded. If the cabinet wall is metal, the hole edge must be covered with a cord protector. NOTE: Power cords with plug must pass through a separate hole. Metal Cabinet Wall Cord Protector (Provided with Power Cord Models Only) Hole Diameter 1-1/2" Maximum Electrical Connection to Dishwasher Electrical connection is on the right front of dishwasher. • For permanent connections, the cable must be routed as shown in Figure E. The cable must extend a minimum of 24" from the rear wall. • For power cord connections, install a 3-prong grounding type receptacle in the adjacent cabinet rear wall, between 6" and 18" from the opening, 6" to 18" above the floor as shown in Figure E. #282 French 5