Attention

Page 22 highlights

Safety information - Ensure that another person, familiar with the power-off controls, is near you. Attention: Another person must be there to switch off the power, if necessary. - Use only one hand when working with powered-on electrical equipment; keep the other hand in your pocket or behind your back. Attention: An electrical shock can occur only when there is a complete circuit. By observing the above rule, you may prevent a current from passing through your body. - When using testers, set the controls correctly and use the approved probe leads and accessories for that tester. - Stand on suitable rubber mats (obtained locally, if necessary) to insulate you from grounds such as metal floor strips and machine frames. Observe the special safety precautions when you work with very high voltages; these instructions are in the safety sections of maintenance information. Use extreme care when measuring high voltages. v Regularly inspect and maintain your electrical hand tools for safe operational condition. v Do not use worn or broken tools and testers. v Never assume that power has been disconnected from a circuit. First, check that it has been powered off. v Always look carefully for possible hazards in your work area. Examples of these hazards are moist floors, nongrounded power extension cables, power surges, and missing safety grounds. v Do not touch live electrical circuits with the reflective surface of a plastic dental mirror. The surface is conductive; such touching can cause personal injury and machine damage. v Do not service the following parts with the power on when they are removed from their normal operating places in a machine: - Power supply units - Pumps - Blowers and fans - Motor generators and similar units. (This practice ensures correct grounding of the units.) v If an electrical accident occurs: - Use caution; do not become a victim yourself. - Switch off power. - Send another person to get medical aid. 18 ThinkPad G40, G41

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164

Ensure
that
another
person,
familiar
with
the
power-off
controls,
is
near
you.
Attention:
Another
person
must
be
there
to
switch
off
the
power,
if
necessary.
Use
only
one
hand
when
working
with
powered-on
electrical
equipment;
keep
the
other
hand
in
your
pocket
or
behind
your
back.
Attention:
An
electrical
shock
can
occur
only
when
there
is
a
complete
circuit.
By
observing
the
above
rule,
you
may
prevent
a
current
from
passing
through
your
body.
When
using
testers,
set
the
controls
correctly
and
use
the
approved
probe
leads
and
accessories
for
that
tester.
Stand
on
suitable
rubber
mats
(obtained
locally,
if
necessary)
to
insulate
you
from
grounds
such
as
metal
floor
strips
and
machine
frames.
Observe
the
special
safety
precautions
when
you
work
with
very
high
voltages;
these
instructions
are
in
the
safety
sections
of
maintenance
information.
Use
extreme
care
when
measuring
high
voltages.
v
Regularly
inspect
and
maintain
your
electrical
hand
tools
for
safe
operational
condition.
v
Do
not
use
worn
or
broken
tools
and
testers.
v
Never
assume
that
power
has
been
disconnected
from
a
circuit.
First,
check
that
it
has
been
powered
off.
v
Always
look
carefully
for
possible
hazards
in
your
work
area.
Examples
of
these
hazards
are
moist
floors,
nongrounded
power
extension
cables,
power
surges,
and
missing
safety
grounds.
v
Do
not
touch
live
electrical
circuits
with
the
reflective
surface
of
a
plastic
dental
mirror.
The
surface
is
conductive;
such
touching
can
cause
personal
injury
and
machine
damage.
v
Do
not
service
the
following
parts
with
the
power
on
when
they
are
removed
from
their
normal
operating
places
in
a
machine:
Power
supply
units
Pumps
Blowers
and
fans
Motor
generators
and
similar
units.
(This
practice
ensures
correct
grounding
of
the
units.)
v
If
an
electrical
accident
occurs:
Use
caution;
do
not
become
a
victim
yourself.
Switch
off
power.
Send
another
person
to
get
medical
aid.
Safety
information
18
ThinkPad