IBM 8670 Installation Guide - Page 21

Non-hot-plug, 64-bit PCI-X slots 3 through 4 PCI bus B, 133 MHz, 32-bit PCI slot 5 PCI bus C

Page 21 highlights

- Non-hot-plug, 64-bit PCI-X slots 3 through 4 (PCI bus B, 133 MHz) - Non-hot-plug, 32-bit PCI slot 5 (PCI bus C, 33 MHz) v The system scans PCI and PCI-X slots 1 through 5 to assign system resources; then, the system starts (boots) the system devices in the following order, if you have not changed the default boot precedence: integrated Ethernet controller, integrated SCSI controller, and then PCI and PCI-X slots 5, 3, 4, 1, and 2. Note: If you are installing an optional ServeRAID-5i controller or other RAID controller, review the following: v No rerouting of the internal SCSI cable is required if you are installing the ServeRAID-5i controller. The ServeRAID-5i controller uses the SCSI connector on the system board for output. v The ServeRAID-5i controller can be installed only in PCI slot 2. v The low-profile 2-U bracket that comes with the controller is required to install the controller. v If the ServeRAID-5i controller is installed, it takes control of the integrated SCSI controller with RAID capabilities and operates at 66 MHz. v To have SCSI capabilities if you remove the ServeRAID-5i controller or other RAID controller, use the Configuration/Setup Utility program to enable the SCSI controller with RAID capabilities. The following illustrations show the location of the PCI and PCI-X adapter expansion slots on the system board and PCI riser card. System board DIMM 1 (J1) DIMM 2 (J2) PCI-X slot 1 64-bit 3.3V 100 MHz (J14) PCI-X slot 2 64-bit 3.3V 100 MHz (J13) Battery (BH1) PCI riser card (J16) DIMM 3 (J3) DIMM 4 (J4) VRM 2 (J5) Microprocessor 2 (J6) Microprocessor 1 (J7) VRM 1 (J8) Chapter 2. Installing options 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77

Non-hot-plug, 64-bit PCI-X slots 3 through 4 (PCI bus B, 133 MHz)
Non-hot-plug, 32-bit PCI slot 5 (PCI bus C, 33 MHz)
v
The system scans PCI and PCI-X slots 1 through 5 to assign system resources;
then, the system starts (boots) the system devices in the following order, if you
have not changed the default boot precedence: integrated Ethernet controller,
integrated SCSI controller, and then PCI and PCI-X slots 5, 3, 4, 1, and 2.
Note:
If you are installing an optional ServeRAID-5i controller or other RAID
controller, review the following:
v
No rerouting of the internal SCSI cable is required if you are installing the
ServeRAID-5i controller. The ServeRAID-5i controller uses the SCSI
connector on the system board for output.
v
The ServeRAID-5i controller can be installed only in PCI slot 2.
v
The low-profile 2-U bracket that comes with the controller is required to
install the controller.
v
If the ServeRAID-5i controller is installed, it takes control of the integrated
SCSI controller with RAID capabilities and operates at 66 MHz.
v
To have SCSI capabilities if you remove the ServeRAID-5i controller or
other RAID controller, use the Configuration/Setup Utility program to
enable the SCSI controller with RAID capabilities.
The following illustrations show the location of the PCI and PCI-X adapter
expansion slots on the system board and PCI riser card.
System board
PCI-X slot 2
64-bit 3.3V
100 MHz
(J13)
PCI-X slot 1
64-bit 3.3V
100 MHz
(J14)
PCI riser
card
(J16)
DIMM 1
(J1)
DIMM 3
(J3)
DIMM 4
(J4)
VRM 2
(J5)
VRM 1
(J8)
DIMM 2
(J2)
Microprocessor 2
(J6)
Microprocessor 1
(J7)
Battery
(BH1)
Chapter 2. Installing options