Installing, non-hot-swap, drive

Page 46 highlights

Installing a non-hot-swap hard disk drive Before you install a non-hot-swap hard disk drive, read the following information: v See the documentation that comes with the drive for any cabling instructions. v Route the cable before you install the drive. Do not block the airflow from the fans. Complete the following steps to install a non-hot-swap hard disk drive: Drive bay 2 Drive bay 1 1. Read "Safety information" on page 101 and "Installation guidelines" on page 25. 2. Turn off the server and all attached peripheral devices. Disconnect all power cords; then, disconnect all external signal cables from the server. 3. Remove the server from the rack; then, remove the server cover (see "Removing the cover and bezel" on page 27). 4. Press in on the USB option tray to release it and slide the tray out until it stops; then, press the retention clip at the bottom rear of the tray and remove the tray from the server. Press on the bezel retention tabs and pull the bezel directly away from the server. Notes: a. If you have only one non-hot-swap hard disk drive, install it in the right-hand bay (bay 2) with a jumper installed in the cable-selection-enabled position of the jumper block on the rear of the drive. b. If you have two drives and you want the server to determine the master drive and subordinate drive automatically, install jumpers in the cable-selection-enabled position of the jumper block on both drives. c. If you want to assign master and subordinate drives manually, install a jumper in the master position for the drive in bay 2 and install a jumper in the subordinate position for the drive in bay 1. 5. Install the hard disk drive in the drive bay: a. Attach the rails to the sides of the drive using 2 screws for each rail. b. Slide the drive into the bay until the rail latches snap into place. c. Connect the signal and power cables to the rear of the drive. Keep the cables clear of the airflow path of the fan behind the drive bays. 6. If you have other options to install, install them now. Otherwise, go to "Completing the installation" on page 47. 36 325 Type 8835: Hardware Maintenance Manual and Troubleshooting Guide Eserver

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164

Installing
a
non-hot-swap
hard
disk
drive
Before
you
install
a
non-hot-swap
hard
disk
drive,
read
the
following
information:
v
See
the
documentation
that
comes
with
the
drive
for
any
cabling
instructions.
v
Route
the
cable
before
you
install
the
drive.
Do
not
block
the
airflow
from
the
fans.
Complete
the
following
steps
to
install
a
non-hot-swap
hard
disk
drive:
Drive bay 1
Drive bay 2
1.
Read
“Safety
information”
on
page
101
and
“Installation
guidelines”
on
page
25.
2.
Turn
off
the
server
and
all
attached
peripheral
devices.
Disconnect
all
power
cords;
then,
disconnect
all
external
signal
cables
from
the
server.
3.
Remove
the
server
from
the
rack;
then,
remove
the
server
cover
(see
“Removing
the
cover
and
bezel”
on
page
27).
4.
Press
in
on
the
USB
option
tray
to
release
it
and
slide
the
tray
out
until
it
stops;
then,
press
the
retention
clip
at
the
bottom
rear
of
the
tray
and
remove
the
tray
from
the
server.
Press
on
the
bezel
retention
tabs
and
pull
the
bezel
directly
away
from
the
server.
Notes:
a.
If
you
have
only
one
non-hot-swap
hard
disk
drive,
install
it
in
the
right-hand
bay
(bay
2)
with
a
jumper
installed
in
the
cable-selection-enabled
position
of
the
jumper
block
on
the
rear
of
the
drive.
b.
If
you
have
two
drives
and
you
want
the
server
to
determine
the
master
drive
and
subordinate
drive
automatically,
install
jumpers
in
the
cable-selection-enabled
position
of
the
jumper
block
on
both
drives.
c.
If
you
want
to
assign
master
and
subordinate
drives
manually,
install
a
jumper
in
the
master
position
for
the
drive
in
bay
2
and
install
a
jumper
in
the
subordinate
position
for
the
drive
in
bay
1.
5.
Install
the
hard
disk
drive
in
the
drive
bay:
a.
Attach
the
rails
to
the
sides
of
the
drive
using
2
screws
for
each
rail.
b.
Slide
the
drive
into
the
bay
until
the
rail
latches
snap
into
place.
c.
Connect
the
signal
and
power
cables
to
the
rear
of
the
drive.
Keep
the
cables
clear
of
the
airflow
path
of
the
fan
behind
the
drive
bays.
6.
If
you
have
other
options
to
install,
install
them
now.
Otherwise,
go
to
“Completing
the
installation”
on
page
47.
36
Eserver
325
Type
8835:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide