Icom ID-52A Ci-v Reference Guide english - Page 5

Data format, Command table, Controller to ID-52A/E, OK message to controller, ID-52A/E to controller

Page 5 highlights

REMOTE CONTROL Remote control (CI-V) information DDData format The CI-V system can be written using the following data formats. Data formats differ according to command numbers. A data area or sub command is added for some commands. Controller to ID-52A/E q w ert y u FE FE A6 E0 Cn Sc Data area FD OK message to controller FE FE E0 A6 FB FD End of message code (fixed) OK code (fixed) Transceiver's default address Controller's default address Preamble code (fixed) Preamble code (fixed) Transceiver's default address Controller's default address Command number (see the command table) Sub command number (see the command table) BCD code data for frequency or memory number entry End of message code (fixed) NG code (fixed) FE FE E0 A6 Cn Sc Data area FD q w ert y u ID-52A/E to controller FE FE E0 A6 FA FD NG message to controller DDCommand table Command Sub 00 01 03 04 05 06 07 D0 D1 0C 0D 0F 10 11 12 Data See p. 6 See p. 6 See p. 6 See p. 6 See p. 6 See p. 6 See p. 6 See p. 6 Description Send operating frequency for transceive Send operating mode for transceive Read operating frequency Read operating mode Send operating frequency Send operating mode Select the VFO mode Select the A band Dualwatch: Set the MAIN band as the A band Single watch: Select the A band Select the B band Dualwatch: Set the MAIN band as the B band Single watch: Select the B band Read offset frequency*1 Set offset frequency Read duplex setting (10=OFF, 11=DUP-, 12=DUP+) Set Simplex Set Duplex - Set Duplex + Command Sub Data Description 11* 00/10/30 Send/read Attenuator (00=OFF, 10=10 dB (375 ~ 479 MHz), 30=30 dB (108 ~ 374.995 MHz) 14* 01 See p. 6 Send/read the audio level 03 See p. 6 Send/read the squelch level 0A See p. 6 Send/read the RF power setting 0B See p. 6 Send/read MIC gain (External) 16 See p. 6 Send/read the VOX gain 15 01 00/01 Read noise or S-meter squelch status (00=Close, 01=Open) 02 0000 ~ 0255 Read S-meter level (0000=S0, 0170=S9) 05 00/01 Read various squelch function's (including the tone squelch) status (00=Close, 01=Open) 11 0000 ~ 0255 Read the Po Meter Level (25=S-Low, 76=Low1, 128=Low2, 179= Mid, 230=High) *(Asterisk) Send/read data 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14

4
REMOTE CONTROL
Remote control (CI-V) information
D
Data format
The CI-V system can be written using the following data formats� Data formats differ according to
command numbers� A data area or sub command is added for some commands�
D
Command table
Command
Sub
Data
Description
00
See p� 6
Send operating frequency for
transceive
01
See p� 6
Send operating mode for transceive
03
See p� 6
Read operating frequency
04
See p� 6
Read operating mode
05
See p� 6
Send operating frequency
06
See p� 6
Send operating mode
07
Select the VFO mode
D0
Select the A band
Dualwatch:
Set the MAIN band as
the A band
Single watch: Select the A band
D1
Select the B band
Dualwatch:
Set the MAIN band as
the B band
Single watch: Select the B band
0C
See p� 6
Read offset frequency*
1
0D
See p� 6
Set offset frequency
0F
Read duplex setting
(10=OFF, 11=DUP–, 12=DUP+)
10
Set Simplex
11
Set Duplex –
12
Set Duplex +
Command
Sub
Data
Description
11*
00/10/30
Send/read Attenuator
(00=OFF, 10=10 dB (375
~
479 MHz),
30=30 dB (108
~
374�995 MHz)
14*
01
See p� 6
Send/read the audio level
03
See p� 6
Send/read the squelch level
0A
See p� 6
Send/read the RF power setting
0B
See p� 6
Send/read MIC gain (External)
16
See p� 6
Send/read the VOX gain
15
01
00/01
Read noise or S-meter squelch status
(00=Close, 01=Open)
02
0000 ~ 0255
Read S-meter level
(0000=S0, 0170=S9)
05
00/01
Read various squelch function’s
(including the tone squelch) status
(00=Close, 01=Open)
11
0000 ~ 0255
Read the Po Meter Level
(25=S-Low, 76=Low1,
128=Low2, 179= Mid, 230=High)
Controller to ID-52A/E
OK message to controller
NG message to controller
ID-52A/E to controller
FE
FE
A6
E0
Cn
Sc
Data area
FD
Preamble
code
(fixed)
Transceiver’s
default address
Controller’s
default address
Command number
(see the command table)
Sub command number
(see the command table)
BCD code data for
frequency or memory
number entry
End of message
code
(fixed)
FE FE
E0
A6
FB
FD
FE FE
E0
A6
FA
FD
Preamble
code
(fixed)
Controller’s
default address
Transceiver’s
default address
OK code
(fixed)
End of message
code
(fixed)
NG code
(fixed)
q
w
e
r
t
y
u
FE
FE
E0
A6
Cn
Sc
Data area
FD
q
w
e
r
t
y
u
*(Asterisk) Send/read data