Icom ID-52A Ci-v Reference Guide english - Page 8
DV TX call signs setting 24 characters, DV MY call sign setting
View all Icom ID-52A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
REMOTE CONTROL Remote control (CI-V) information DDCommand formats •• Repeater tone/tone squelch frequency setting Command: 1B 00, 1B 01 q* 00 w XX e XX Fixed: 0 Fixed: 0 100 Hz digit 10 Hz digit 10 Hz digit 0�1 Hz digit Fixed: 0 First digit: 0~7 Second digit: 0~7 Third digit: 0~7 *No input required when setting the frequency� Refer to the Advanced manual for the tone frequency list. •• DTCS code and polarity setting Command: 1B 02 qwe XX0XXX Receive polarity: 0: Normal 1: Reverse Transmit polarity: 0: Normal 1: Reverse Refer to the Advanced manual for the DTCS code list. •• Digital code squelch setting Command: 1B 07 q XX •• DV MY call sign setting Command: 1F 00 Set your own call sign and note of up to 12 characters. See "Character's code of the call sign." 1 ~ 8 9 ~ 12 X X X X X X X X X X X X 1 ~ 8: Your own call sign setting (8 characters) 9 ~ 12: Note setting (4 characters) •• DV TX call signs setting (24 characters) Command: 1F 01 Set "UR," "R1," and "R2" call signs of 8 characters (fixed). See "Character's code of the call sign." 1 ~ 8 9 ~ 16 17 ~ 24 X X X X X X X X X X X X 1 ~ 8: U R (Destination) call sign setting (8 characters) 9 ~ 16: R 1 (Access/Area repeater) call sign setting (8 characters) 17 ~ 24: R 2 (Link/Gateway repeater) call sign setting (8 characters) Character's code of the call sign Character ASCII code 0 ~ 9 30 ~ 39 A ~ Z 41 ~ 5A (Space) 20 / 2F First digit: 0~9 Second digit: 0~9 7