Intel BOXD510MO Product Guide - Page 54

BIOS Front-panel Power LED Blink Codes, POST Error Messages, Table 19. POST Error Messages

Page 54 highlights

Intel Desktop Board D510MO Product Guide BIOS Front-panel Power LED Blink Codes The BIOS also blinks the front-panel power LED to signal status messages and error messages indicating certain recoverable errors that occur during the POST. The blink codes are listed in Table 18. Table 18. BIOS Front-panel Power LED Blink Codes Type BIOS update in progress Video error Memory error Thermal trip warning Pattern Note Off when the update begins, then on for 0.5 second, and then off for 0.5 second. The pattern repeats until the BIOS update is complete. On-off (1.0 second each) two times, then a 2.5-second pause (off); the entire pattern repeats (blinks and pause) until the system is powered off. When no VGA option ROM is found. On-off (1.0 second each) three times, then a 2.5-second pause (off); the entire pattern repeats (blinks and pause) until the system is powered off. Each beep will be accompanied by the following blink pattern: 0.25 second on, 0.25 second off, 0.25 second on, 0.25 second off. This results in a total of 16 blinks followed by system shut down. POST Error Messages The BIOS also displays error messages on the video monitor when certain recoverable errors occur during the POST. Table 19 lists the error messages with a brief description of each. Table 19. POST Error Messages Error Message CMOS Battery Low CMOS Checksum Bad Memory Size Decreased No Boot Device Available Explanation The battery may be losing power. The CMOS checksum is incorrect. The CMOS memory may have been corrupted. Run Setup to reset values. Memory size has decreased since the last boot. If no memory was removed, then memory may be bad. System did not find a device to boot. 54

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66

Intel Desktop Board D510MO Product Guide
54
BIOS Front-panel Power LED Blink Codes
The BIOS also blinks the front-panel power LED to signal status messages and error
messages indicating certain recoverable errors that occur during the POST.
The blink
codes are listed in Table 18.
Table 18. BIOS Front-panel Power LED Blink Codes
Type
Pattern
Note
BIOS update in
progress
Off when the update begins, then on for
0.5 second, and then off for 0.5 second.
The pattern repeats until the BIOS update
is complete.
Video error
On-off (1.0 second each) two times, then a
2.5-second pause (off); the entire pattern
repeats (blinks and pause) until the system
is powered off.
When no VGA option ROM
is found.
Memory error
On-off (1.0 second each) three times, then
a 2.5-second pause (off); the entire pattern
repeats (blinks and pause) until the system
is powered off.
Thermal trip warning
Each beep will be accompanied by the
following blink pattern:
0.25 second on,
0.25 second off, 0.25 second on,
0.25 second off.
This results in a total of
16 blinks followed by system shut down.
POST Error Messages
The BIOS also displays error messages on the video monitor when certain recoverable
errors occur during the POST.
Table 19 lists the error messages with a brief
description of each.
Table 19. POST Error Messages
Error Message
Explanation
CMOS Battery Low
The battery may be losing power.
CMOS Checksum Bad
The CMOS checksum is incorrect.
The CMOS memory
may have been corrupted.
Run Setup to reset values.
Memory Size Decreased
Memory size has decreased since the last boot.
If no
memory was removed, then memory may be bad.
No Boot Device Available
System did not find a device to boot.