Removing Upper Blower Assembly, Blower, Speed Resistor, And Oven Thermal Cutoff

Page 42 highlights

REMOVING UPPER BLOWER ASSEMBLY, BLOWER SPEED RESISTOR, AND OVEN THERMAL CUTOFF WARNING 4. Remove the twelve screws from the upper rear cover of the oven and remove the cover. Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. 1. Unplug oven or disconnect power. Upper Rear Cover (12 Screws) WARNING Excessive Weight Hazard Use two or more people to move and install oven. Failure to do so can result in back or other injury. 2. Remove the oven from its mounting location (see "Installation Information" in Section 2) and pull it forward so that you can access the top cover. 3. Remove the six screws from the top cover and remove the cover. Top Cover Screws (3 of 6) Blower Blower Motor Oven Shutdown TCO 5. To remove the blower assembly: a) Disconnect the white and gray wires from the blower motor terminals. b) Remove the two screws from the blower brackets. c) Pull back on the blower assembly while rotating it upwards and remove the assembly. Screws Blower Motor Wires 4-16

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90

4-16
REMOVING UPPER BLOWER ASSEMBLY, BLOWER
SPEED RESISTOR, AND OVEN THERMAL CUTOFF
WARNING
4.
Remove the twelve screws from the upper
rear cover of the oven and remove the
cover.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
Upper Rear Cover
(12 Screws)
1.
Unplug oven or disconnect power.
Blower Motor
Oven Shutdown
TCO
5.
To remove the blower assembly:
a) Disconnect the white and gray wires
from the blower motor terminals.
b)
Remove the two screws from the blower
brackets.
c)
Pull back on the blower assembly while
rotating it upwards and remove the as-
sembly.
Blower Motor Wires
Screws
Blower
Top Cover
Screws (3 of 6)
2.
Remove the oven from its mounting location
(see “Installation Information” in Section 2)
and pull it forward so that you can access
the top cover.
3.
Remove the six screws from the top cover
and remove the cover.
Excessive Weight Hazard
Use two or more people to move and
install oven.
Failure to do so can result in back or
other injury.
WARNING