ENGLISH INSTALLATION 11 Closet Ventilation Requirements Closets with doors must have both an upper and lower vent to prevent heat and moisture buildup in the closet. One upper vent opening with a minimum opening of 48 sq. in. (310 cm2) must be installed no lower than 6 feet above the floor. One lower vent opening with a minimum opening of 24 sq. in. (155 cm2) must be installed no more than one foot above the floor. Install vent grills in the door or cut down the door at the top and bottom to form openings. Louvered doors with equivalent ventilation openings are also acceptable. NOTE There should be at least a little space around the dryer (or any other appliance) to eliminate the transfer of vibration from one appliance to another. If there is enough vibration, it could cause appliances to make noise or come into contact, causing paint damage and further increasing noise. Installation Spacing for Recessed Area or Closet 3" (7.6 cm) 48 in.2 (310 cm2) 21 1/4" (54 cm) 14" max.* (35.6 cm) 18" min. (45.7 cm) 24 in.2 (155 cm2) Closet Door Vent 3" Requirements (7.6 cm) 29 1/2" (75.0 cm) 50 1/4" (127.5 cm) * Required spacing ** For side or bottom venting, 2-inch (5.1 cm) of spacing is allowed 1" (2.5 cm) 27" (68.6 cm) 1" (2.5 cm) Installation Spacing for Cabinet For cabinet installation with a door, minimum ventilation openings in the top of the cabinet are required. * Required spacing 7"* (17.8 cm) 7"* (17.8 cm) 5"* 29 1/2" (12.7 cm) (75.0 cm) 1"* (2.5 cm) 1" (2.5 cm) 27" (68.6 cm) 1" (2.5 cm) MFL70442605_en_190215.indd 11 2019-02-15 오후 2:38:15