LG DLGX7901WE Owners Manual - Page 28

Four-Wire Power Cord, Terminal Block, UL-Listed, Strain Relief, UL-Listed 4-Wire Power Cord, Neutral

Page 28 highlights

28 INSTALLATION WARNING Connect the power cord to the terminal block. Each colored wire should be connected to the same color screw. Wire color indicated on manual is connected to the same color screw in the block. Failure to follow these instructions may result in a short or overload. Grounding through the neutral conductor is prohibited for: (1) new branch-circuit installations, (2) areas where local codes prohibit grounding through the neutral conductor. Four-Wire Power Cord •• A UL-listed strain relief is required. •• Use a 30-amp, 240-volt, 4-wire, ULlisted power cord with #10 AWGminimum copper conductor and closed loop or forked terminals with upturned ends. 6 Attach the white neutral wire to the center screw of the terminal block. 7 Attach the power cord ground wire to the green ground screw. 8 Tighten all screws securely. 9 Reinstall the terminal block access cover. Hot Neutral (Black) (White) Ground Screw Power Cord Ground Wire Hot (Red) White Wire moved from Ground Screw 1 Remove the terminal block access cover on the upper back of the dryer. 2 Install a UL-listed strain relief into the power cord through-hole. 3 Thread a 30-amp, 240-volt, 4-wire, UL-listed power cord with #10 AWG-minimum copper conductor through the strain relief. Terminal Block UL-Listed Strain Relief UL-Listed 4-Wire Power Cord 4 Transfer the dryer's ground wire from behind the green ground screw to the center screw of the terminal block. NOTE This dryer is supplied with the neutral wire grounded. This white ground wire MUST BE MOVED to the neutral terminal when a 4-wire cord is to be used, or where grounding through the neutral conductor is prohibited. 5 Attach the two hot leads of the power cord to the outer terminal block screws.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128

28
INSTALLATION
WARNING
Connect the power cord to the terminal block.
Each colored wire should be connected to the
same color screw. Wire color indicated on manual
is connected to the same color screw in the block.
Failure to follow these instructions may result in a
short or overload.
Grounding through the neutral conductor is
prohibited for: (1) new branch-circuit installations,
(2) areas where local codes prohibit grounding
through the neutral conductor.
Four-Wire Power Cord
A UL-listed strain relief is required.
Use a 30-amp, 240-volt, 4-wire, UL-
listed power cord with #10 AWG-
minimum copper conductor and closed
loop or forked terminals with upturned
ends.
1
Remove the terminal block access cover on the
upper back of the dryer.
2
Install a UL-listed strain relief into the power cord
through-hole.
3
Thread a 30-amp, 240-volt, 4-wire, UL-listed
power cord with #10 AWG-minimum copper
conductor through the strain relief.
Terminal Block
UL-Listed
Strain Relief
UL-Listed 4-Wire Power Cord
4
Transfer the dryer’s ground wire from behind the
green ground screw to the center screw of the
terminal block.
NOTE
This dryer is supplied with the neutral wire
grounded. This white ground wire MUST BE
MOVED to the neutral terminal when a 4-wire
cord is to be used, or where grounding through
the neutral conductor is prohibited.
5
Attach the two hot leads of the power cord to the
outer terminal block screws.
6
Attach the white neutral wire to the center screw
of the terminal block.
7
Attach the power cord ground wire to the green
ground screw.
8
Tighten all screws securely.
9
Reinstall the terminal block access cover.
Hot
(Red)
Neutral
(White)
Hot
(Black)
Ground
Screw
Power Cord
Ground Wire
White Wire
moved from
Ground
Screw