LG DLGX7901WE Owners Manual - Page 29
Four-Wire Direct Wire, Use UL-listed 4-wire #10 AWG
View all LG DLGX7901WE manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
Four-Wire Direct Wire •• A UL-listed strain relief is required. •• Use UL-listed 4-wire #10 AWG- minimum copper conductor cable. Allow at least 5 ft. (1.5 m) of wire to allow for removal and reinstallation of the dryer. 1 Remove 5-inch (12.7 cm) of the outer covering from the wire. Remove 5-inch (12.7 cm) of insulation from the ground wire. Cut off approximately 1½-inch (3.8 cm) from the other three wires and strip 1 inch (2.5 cm) insulation from each wire. Bend the ends of the three shorter wires into a hook shape. 1" (2.5 cm) Ground Wire 5" (12.7 cm) 2 Remove the terminal block access cover on the upper back of the dryer. 3 Install a UL-listed strain relief into the power cord through-hole. 4 Thread the 4-wire #10 AWG-minimum copper power cable prepared in step 1 through the strain relief. Terminal Block UL-Listed Strain Relief INSTALLATION 29 7 Attach the white neutral wire to the center screw of the terminal block. 8 Attach the power cord ground wire to the green ground screw. 9 Tighten all screws securely. 10 Reinstall the terminal block access cover. Ground Screw Hot Neutral (Black) (White) Power Cord Ground Wire Hot (Red) White Wire moved from Ground Screw UL-Listed 4-Wire Power Cord 5 Transfer the dryer's ground wire from behind the green ground screw to the center screw of the terminal block. NOTE This dryer is supplied with the neutral wire grounded. This white ground wire MUST BE MOVED to the neutral terminal when a 4-wire cord is to be used, or where grounding through the neutral conductor is prohibited. 6 Attach the two hot leads of the power cord to the outer terminal block screws.