1 Boot block recovery jumper (J42) 2 Switch block (SW2) To clear CMOS and reset the passwords, complete the following steps: 1. Read the safety information that begins on page v and "Installation guidelines" on page 29. 2. Turn off the server and peripheral devices and disconnect all power cords and external cables. Attention: In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc power supply and to install and remove a dc power supply. See the documentation that comes with each dc power supply. 3. Remove the server from the rack and place it on a flat, static-protective surface. 4. Remove the cover. See "Removing the cover" on page 31 for instructions. 5. Move the clear-CMOS switch (switch 1 on SW2) to the On position. 6. Install the cover and connect the server to a keyboard, monitor, and mouse; then, connect the server to a power source. 86 ThinkServer RD120 Types 6444, 6445, 6446, and 6447: User Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118

±1²
Boot
block
recovery
jumper
(J42)
±2²
Switch
block
(SW2)
To
clear
CMOS
and
reset
the
passwords,
complete
the
following
steps:
1.
Read
the
safety
information
that
begins
on
page
v
and
“Installation
guidelines”
on
page
29.
2.
Turn
off
the
server
and
peripheral
devices
and
disconnect
all
power
cords
and
external
cables.
Attention:
In
a
dc
power
environment,
only
trained
service
personnel
other
than
Lenovo
service
technicians
are
authorized
to
connect
or
disconnect
power
to
the
dc
power
supply
and
to
install
and
remove
a
dc
power
supply.
See
the
documentation
that
comes
with
each
dc
power
supply.
3.
Remove
the
server
from
the
rack
and
place
it
on
a
flat,
static-protective
surface.
4.
Remove
the
cover.
See
“Removing
the
cover”
on
page
31
for
instructions.
5.
Move
the
clear-CMOS
switch
(switch
1
on
SW2)
to
the
On
position.
6.
Install
the
cover
and
connect
the
server
to
a
keyboard,
monitor,
and
mouse;
then,
connect
the
server
to
a
power
source.
86
ThinkServer
RD120
Types
6444,
6445,
6446,
and
6447:
User