2.5-inch drives To install a drive in a hot-swap bay, complete the following steps. Attention: To maintain proper system cooling, do not operate the server for more than 10 minutes without either a drive or a filler panel installed in each bay. 1. Read the safety information that begins on page v and "Installation guidelines" on page 29. 2. Remove the filler panel from one of the empty hot-swap bays. v 3.5-inch models: Insert your finger into the depression at the left side of the filler panel and pull it away from the server. v 2.5-inch models: Grasp both sides of the front of the filler panel and pull it away from the server. 3. Install the hard disk drive in the hot-swap bay: a. Make sure that the tray handle is open (that is, perpendicular to the drive). b. Align the drive assembly with the guide rails in the bay. c. Gently push the drive assembly into the bay until the drive stops. d. Push the tray handle to the closed (locked) position. e. Check the hard disk drive status LED to verify that the hard disk drive is operating correctly. If the amber hard disk drive status LED for a drive is lit continuously, that drive is faulty and must be replaced. If the green hard disk drive activity LED is flashing, the drive is being accessed. Note: You might have to reconfigure the disk arrays after you install hard disk drives. See the RAID documentation on the IBM ServeRAID Support CD for information about these RAID controllers. If you have other optional devices to install or remove, do so now. Otherwise, go to "Completing the installation" on page 74. 48 ThinkServer RD120 Types 6444, 6445, 6446, and 6447: User Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118

2.5-inch
drives
To
install
a
drive
in
a
hot-swap
bay,
complete
the
following
steps.
Attention:
To
maintain
proper
system
cooling,
do
not
operate
the
server
for
more
than
10
minutes
without
either
a
drive
or
a
filler
panel
installed
in
each
bay.
1.
Read
the
safety
information
that
begins
on
page
v
and
“Installation
guidelines”
on
page
29.
2.
Remove
the
filler
panel
from
one
of
the
empty
hot-swap
bays.
v
3.5-inch
models:
Insert
your
finger
into
the
depression
at
the
left
side
of
the
filler
panel
and
pull
it
away
from
the
server.
v
2.5-inch
models:
Grasp
both
sides
of
the
front
of
the
filler
panel
and
pull
it
away
from
the
server.
3.
Install
the
hard
disk
drive
in
the
hot-swap
bay:
a.
Make
sure
that
the
tray
handle
is
open
(that
is,
perpendicular
to
the
drive).
b.
Align
the
drive
assembly
with
the
guide
rails
in
the
bay.
c.
Gently
push
the
drive
assembly
into
the
bay
until
the
drive
stops.
d.
Push
the
tray
handle
to
the
closed
(locked)
position.
e.
Check
the
hard
disk
drive
status
LED
to
verify
that
the
hard
disk
drive
is
operating
correctly.
If
the
amber
hard
disk
drive
status
LED
for
a
drive
is
lit
continuously,
that
drive
is
faulty
and
must
be
replaced.
If
the
green
hard
disk
drive
activity
LED
is
flashing,
the
drive
is
being
accessed.
Note:
You
might
have
to
reconfigure
the
disk
arrays
after
you
install
hard
disk
drives.
See
the
RAID
documentation
on
the
IBM
ServeRAID
Support
CD
for
information
about
these
RAID
controllers.
If
you
have
other
optional
devices
to
install
or
remove,
do
so
now.
Otherwise,
go
to
“Completing
the
installation”
on
page
74.