Wiring a Door Sensing Device / AutoCall Wiring a Door Sensing Device The units can monitor the position of up to four doors/gates and may react to a change in their status with one of the relays (not set as a control relay). For example, if a door is pried open or is held open after its relay deactivates, the unit will record the breach in its transactions and can perform the following actions: • Energize a relay to activate an alarm device such as a siren, light or CCTV camera. • Main use is to terminate strike time early. EXIT REQ 4 COM DOOR STAT 4 EXIT REQ 3 COM DOOR STAT 3 EXIT REQ 2 COM DOOR STAT 4 EXIT REQ 1 COM DOOR STAT 1 J7 J6 POSTAL J3 AUTO J5 J2 J1 POWER 12VAC/DC Common J4 IO Input Board Door Status Input Board (See page 6) Use 18-24 AWG NOTE: Additional sensing devices can be connected to any of the 4 Door Stat inputs. NOTE: Door sensing device should provide contact closure when door is closed. Wiring the AutoCall Feature Using the AutoCall feature, the unit will automatically call the main residence phone when a driveway sensor is activated (any device that provides a contact closure). For example, when a visitor drives over a loop sensor that is connected to the AutoCall feature, the unit will call the main residence phone automatically so the visitor can speak to the resident without pressing the call button on the unit. J6 POSTAL J3 AUTO J5 J2 J1 POWER 12VAC/DC J4 IO Input Board Input Board (See page 6) In Common Use 18-24 AWG Loop Detector SenLsooorp Page 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

Page 17
Wiring a Door Sensing Device / AutoCall
Wiring a Door Sensing Device
The units can monitor the position of up to
four doors/gates
and may react to a change in their status with one of
the relays (not set as a control relay). For example, if a door is pried open or is held open after its relay deactivates,
the unit will record the breach in its transactions and can perform the following actions:
• Energize a relay to activate an alarm device such as a siren, light or CCTV camera.
• Main use is to terminate strike time early.
Wiring the AutoCall Feature
Using the AutoCall feature, the unit will automatically call the main residence phone when a driveway sensor is
activated
(any device that provides a contact closure). For example, when a visitor drives over a
loop sensor
that
is connected to the AutoCall feature, the unit will call the main residence phone automatically so the visitor can
speak to the resident
without
pressing the call button on the unit.
IO Input Board
J2
J3
DOOR
STAT 4
EXIT
REQ 4
COM
DOOR
STAT 3
EXIT
REQ 3
COM
DOOR
STAT 4
EXIT
REQ 2
COM
DOOR
STAT 1
EXIT
REQ 1
COM
J5
J7
J6
J4
POSTAL
AUTO
J1
POWER
12VAC/DC
Use 18-24 AWG
Door Status
Common
Input Board
(See page 6)
NOTE:
Additional sensing devices can be
connected to any of the 4 Door Stat inputs.
IO Input Board
J2
J3
J5
J6
J4
POSTAL
AUTO
J1
POWER
12VAC/DC
Loop
Detector
Use
18-24 AWG
Common
In
Loop
Sensor
Input Board
(See page 6)
NOTE:
Door sensing device should provide contact closure when door is closed.