Control Connection Diagram

Page 32 highlights

CONTROL CONNECTION DIAGRAM 41B6 IMPORTANT NOTES: The 3-Button Control Station provided must be connected for operation.  If a STOP button is not used, a jumper must be placed between terminals 4 and 5. LISTED DOOR OPERATOR 3 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER AND STOP BUTTON STANDARD 2 OR MORE KEY LOCKOUT 10 7 6 4 5 10 7 6 4 5 10 7 6 4 5 (RED) Maintenance Alert LED (WHITE) Open Close Stop (RED) Maintenance Alert LED (WHITE) Open Close Stop Open Close Stop (RED) Maintenance Alert LED (WHITE) Open Close Stop Keyswitch 2 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER STANDARD 764 764 2 OR MORE Open D1 & E2 MODE ONLY Close  See Note 1 BUTTON STATION OR ANY AUXILIARY DEVICE OPEN / CLOSE 14 B2, T, TS & FSTS MODE ONLY  See Note Open Open D1 & E2 MODE ONLY Close Close RADIO CONTROLS OPEN / CLOSE R1 R2 R3  See Note Any Commercial Type LiftMaster Brand Receiver SENSING DEVICE TO REVERSE OR STOP Note: 11 & 4 are both the same common Either is acceptable 11 8 EXTERNAL INTERLOCK Remove Factory Installed Jumper When Interlock is Used 2 3 2 3 01-19969C Sensing Device ONE 2 OR MORE All Wiring Types c 2004, The Chamberlain Group, Inc. All rights Reserved

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

c 200
4
, The Chamberlain Group, Inc.
All rights Reserved
01-19969
C
OPEN / CLOSE
3 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER AND STOP BUTTON
2 OR MORE
KEY LOCKOUT
R1
R2
R3
7
6
4
5
Stop
Close
Open
Stop
Close
Open
7
6
4
5
Stop
Close
Open
2 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER
STANDARD
7
6
4
Close
Open
D1 & E2
MODE ONLY
2 OR MORE
7
6
4
Close
Open
Close
Open
D1 & E2
MODE ONLY
OPEN / CLOSE
1
4
B2, T, TS & FSTS
MODE ONLY
Any Commercial Type
LiftMaster Brand Receiver
1 BUTTON STATION OR ANY AUXILIARY DEVICE
RADIO CONTROLS
SENSING DEVICE TO REVERSE OR STOP
EXTERNAL INTERLOCK
11
8
2
3
2
3
Remove Factory Installed Jumper
When Interlock is Used
ONE
2 OR MORE
STANDARD
7
6
4
5
Stop
Close
Open
IMPORTANT NOTES:
The 3-Button Control Station provided must be connected for operation.
If a STOP button is not used, a jumper must be placed between terminals 4 and 5.
All Wiring Types
Keyswitch
Sensing Device
10
Maintenance
Alert LED
10
10
Maintenance
Alert LED
Maintenance
Alert LED
(RED)
(WHITE)
(RED)
(WHITE)
(RED)
(WHITE)
Note: 11 & 4 are both the same common
Either is acceptable
See Note
See Note
See Note
LISTED
DOOR
OPERATOR
41B6
CONTROL CONNECTION DIAGRAM