LiftMaster H J - NEW STYLE DISCONNECT Manual - Page 7

Entrapment Protection Accessories (optional), Limit Switch Adjustment

Page 7 highlights

ENTRAPMENT PROTECTION ACCESSORIES (OPTIONAL) PHOTO EYES & SENSING EDGES Sensing devices supplied for door industry type operators with an isolated normally open (N.O.) dry contact output are compatible with your operator. This includes through beam and retro reflective photo eyes and pneumatic and electric edges. If your door does not have bottom safety photo eyes or safety edge and you wish to add a safety device to your application, please contact your local LiftMaster Authorized Dealer. If not pre-installed by the door manufacturer, mount the sensing edge on the door according to the instructions provided with the edge. The sensing edge may be electrically connected by either coiled cord or take-up reel. Important Notes: a) Proceed with Limit Switch Adjustments before making any sensing edge wiring connections to operator as described below. b) Electrician must hardwire the junction box to the operator electrical box in accordance with local codes. NOTICE IT IS STRONGLY RECOMMENDED THAT A SAFETY PHOTO EYE OR SENSING EDGE BE USED IN CONJUNCTION WITH THE OPERATOR. WIRING: For wiring of your sensing device to the operator, refer to the wiring diagrams supplied on pages 13 and 14. See field connection terminals identified as Reversing Edge. TAKE-UP REEL: Take-up reel should be installed 12" above the top of the door. COIL CORD: Connect operator end of coil cord to junction box (not supplied) fastened to the wall approximately halfway up the door opening. LIMIT SWITCH ADJUSTMENT MAKE SURE THE LIMIT NUTS ARE POSITIONED BETWEEN THE LIMIT SWITCH ACTUATORS BEFORE PROCEEDING WITH ADJUSTMENTS. 1. To adjust limit nuts depress retaining plate to allow nut to spin freely. After adjustment, release plate and ensure it seats fully in slots of both nuts. 2. To increase door travel, spin nut away from actuator. To decrease door travel, spin limit nut toward actuator. 3. Adjust open limit nut so that door will stop in open position with the bottom of the door even with top of door opening. 4. Repeat Steps 1 and 2 for close cycle. Adjust close limit nut so that actuator is engaged as door fully seats at the floor. WARNING TO AVOID SERIOUS PERSONAL INJURY OR DEATH FROM ELECTROCUTION, DISCONNECT ELECTRIC POWER BEFORE MANUALLY MOVING LIMIT NUTS. If other problems persist, call our toll-free number for CAUTION assistance - 1-800-528-2806. OPEN Limit Switch CLOSE Limit Switch Actuator WA Retaining Plate SAFETY (Aux. Close) Limit Switch 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

7
TO AVOID SERIOUS PERSONAL INJURY OR DEATH
FROM ELECTROCUTION, DISCONNECT ELECTRIC
POWER BEFORE MANUALLY MOVING LIMIT NUTS.
WARNING
LIMIT SWITCH ADJUSTMENT
MAKE SURE THE LIMIT NUTS ARE POSITIONED BETWEEN THE LIMIT SWITCH ACTUATORS BEFORE
PROCEEDING WITH ADJUSTMENTS.
If other problems persist, call our toll-free number for
assistance - 1-800-528-2806.
1.
To adjust limit nuts depress retaining plate to allow
nut to spin freely.
After adjustment, release plate
and ensure it seats fully in slots of both nuts.
2.
To
increase
door travel, spin nut
away
from actu-
ator. To
decrease
door travel, spin limit nut
toward
actuator.
3.
Adjust open limit nut so that door will stop in open
position with the bottom of the door even with top
of door opening.
4.
Repeat Steps 1 and 2 for close cycle. Adjust close
limit nut so that actuator is engaged as door fully
seats at the floor.
Retaining Plate
CLOSE
Limit Switch
SAFETY
(Aux. Close) Limit Switch
OPEN
Limit Switch
Actuator
PHOTO EYES & SENSING EDGES
Sensing devices supplied for door industry type operators
with an isolated normally open (N.O.) dry contact output are
compatible with your operator. This includes through beam
and retro reflective photo eyes and pneumatic and electric
edges.
If your door does not have
bottom safety photo eyes
or safety edge and you wish to add a safety device to your
application, please contact your local LiftMaster Authorized
Dealer.
If not pre-installed by the door manufacturer, mount the sens-
ing edge on the door according to the instructions provided
with the edge.
The sensing edge may be electrically con-
nected by either coiled cord or take-up reel.
Important Notes:
a)
Proceed with Limit Switch Adjustments before making
any sensing edge wiring connections to operator as
described below.
b)
Electrician must hardwire the junction box to the operator
electrical box in accordance with local codes.
ENTRAPMENT PROTECTION ACCESSORIES (OPTIONAL)
WIRING:
For wiring of your sensing device to the operator, refer to
the wiring diagrams supplied on pages 13 and 14.
See
field connection terminals identified as Reversing Edge.
TAKE-UP REEL:
Take-up reel should be installed 12"
above the top of the door.
COIL CORD:
Connect operator end of coil cord to junc-
tion box (not supplied) fastened to the wall approximately
halfway up the door opening.
IT IS STRONGLY
RECOMMENDED THAT A
SAFETY PHOTO EYE OR SENSING EDGE BE
USED IN CONJUNCTION WITH THE OPERATOR.
NOTICE