LiftMaster HCTDCU HCTDCU Installation Manual - Page 28
Miscellaneous Wiring, Three Button Control Station, Fire Department Open Input, Accessory Power 24 Vdc
View all LiftMaster HCTDCU manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
ACCESSORY WIRING MISCELLANEOUS WIRING THREE BUTTON CONTROL STATION (4 Terminals) • OPEN and COM: Opens a closed gate/door. Hard open (maintained switch overrides external safeties and resets alarm condition). If maintained, pauses Timer-to-Close at OPEN limit. Opens a closing gate/door and holds open an open gate/door (within line-of-sight). • CLOSE and COM: Closes an open gate/door. Hard close (maintained switch overrides external safeties and resets alarm condition within line-of-sight) • STOP and COM: Stops a moving gate/door. Hard stop (maintained switch overrides Open and Close commands and resets alarm condition). Cancels/resets Timer-to-Close at OPEN limit. Overrides Open and Close commands (within line-of-sight). FIRE DEPARTMENT OPEN INPUT (2 Terminals) Acts as hard open. Hard open (maintained switch overrides external safeties and resets alarm condition). If maintained, pauses Timer-to-Close at OPEN limit. Opens a closing gate/door and holds open an open gate/door (within lineof-sight). Bypasses any pre-warning delay. ACCESSORY POWER 24 VDC, MAX 500 MA (4 Terminals) • SWITCHED: Switched ON when the gate/door is in motion. Turns off after a 5 second delay when the gate/door stops. The power will remain ON at the open limit when Timer-to-Close is enabled and when the Timer-to-Close is counting down. • UNSWITCHED: 24 Vdc voltage out to power accessories, always ON. (Main control board) Three Button Control Station Open Close Stop N.C. Com Fire Dept Com Fire Department (Main control board) Accessory Power Switched Com (-) Acc Power +24 Vdc Com (-) Acc Power +24 Vdc Accessory Power Unswitched 28