Makita AC310H Owners Manual - Page 2
Explanation of general view, SPECIFICATIONS - air compressor
View all Makita AC310H manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
ENGLISH Explanation of general view 1. Air Tank pressure gauge 2. Regulated presusre gauge "HP" 3. Air regulator "HP" 4. Quick couplers "HP" (Air outlet) 5. Regulated Pressure gauge "RP" 6. Air regulator "RP" 7. Quick coupler "RP" (Air outlet) 8. Drain valve 9. Pressure Switch 9 7 51 2 4 6 3 8 SPECIFICATIONS Model MAX Output Power SCFM @ 40 PSIG SCFM @ 90 PSIG SCFM @ 300 PSIG Cut-In Pressure Cut-Out Pressure Bore x Stroke x Qty Voltage -Single Phase Hz Motor RPM Lubrication Tank Size Weight Dimensions (L x H x W) Outlet Max Pressure "HP" (Exclusively for High Pressure Pneumatic Use) Outlet Max Pressure "RP" (Exclusively for Regular Pressure Pneumatic Use) CSA/US Listed AC310H 1500 W 3.7 3.6 2.7 330 PSIG (2.3 MPa) 400 PSIG (2.8 MPa) 62 mm x 31 mm x 1, 145 mm x 10 mm x 1 120 V AC 60 Hz 1700 min-1 Oil-Less 1.6 gal (6.2 L) 36 kg (79.4 lb) 18-3/4" x 14-3/4" x 20" (476 x 375 x 507 mm) 375 PSIG (2.6 MPa) 130 PSIG (0.9 MPa) Yes • Due to our continuing programme of research and development, the specifications herein are subject to change without notice. • Note: Specifications may differ from country to country. Minimum Circuit Requirement: 15 AMPS * A circuit breaker is preferred. Use only a fuse or circuit breaker that is the same rating as the branch circuit the air compressor is operated on. If the air compressor is connected to a circuit protected by fuses, use time delay fuses. IMPORTANT Read the Safety Guidelines and ALL instructions carefully before operating. www.makitatools.com www.makita.ca 2