Netgear GSM7252PS GSM72xxPS and GSM73xxSv2 Series Managed Switch Hardware Inst - Page 28

Troubleshooting

Page 28 highlights

Troubleshooting 3 Troubleshooting Chart The following table lists symptoms, causes, and solutions of possible problems. Table 3-1. Troubleshooting Chart Problem Cause Solution Power LED is off. No power is received Check the power cord connections for the switch at the switch and the connected device. Make sure that all cables used are correct and comply with Ethernet specifications. Link LED is off or intermittent. Port connection is not working. • Check the crimp on the connectors. Make sure the plug is fully inserted and locked into the port at both the switch and the connecting device. • Make sure that all cables used are correct and comply with Ethernet specifications. See Appendix A. • Check for a defective adapter card, cable, or port by testing it in an alternate environment where all products are functioning. Slow file transfer or there is performance degradation. Half- or full-duplex setting on • Make sure that the attached device is set to the switch and the connected auto negotiate. device are not the same. • Check the system message log. A segment or device is not recognized as part of the network. One or more devices are not Verify that the cabling is correct. Be sure that all properly connected, or cabling connectors are securely positioned in the does not meet Ethernet required ports. Equipment may have been guidelines. accidentally disconnected. ACT LED flashes continuously on all connected ports and the network is disabled. A network loop (redundant path) has been created. Break the loop by ensuring that there is only one path from any networked device to any other networked device. Chapter 3: Troubleshooting | 29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39

Chapter 3:
Troubleshooting
|
29
Troubleshooting
3
Troubleshooting Chart
The following table lists symptoms, causes, and solutions of possible problems.
Table 3-1.
Troubleshooting Chart
Problem
Cause
Solution
Power LED is off.
No power is received
Check the power cord connections for the switch
at the switch and the connected device.
Make sure that all cables used are correct and
comply with Ethernet specifications.
Link LED is off or intermittent.
Port connection is not
working.
Check the crimp on the connectors. Make
sure the plug is fully inserted and locked into
the port at both the switch and the
connecting device.
Make sure that all cables used are correct
and comply with Ethernet specifications.
See
Appendix A
.
Check for a defective adapter card, cable,
or port by testing it in an alternate
environment where all products are
functioning.
Slow file transfer or there is
performance degradation.
Half- or full-duplex setting on
the switch and the connected
device are not the same.
Make sure that the attached device is set to
auto negotiate.
Check the system message log.
A segment or device is not
recognized as part of the
network.
One or more devices are not
properly connected, or cabling
does not meet Ethernet
guidelines.
Verify that the cabling is correct. Be sure that all
connectors are securely positioned in the
required ports. Equipment may have been
accidentally disconnected.
ACT LED flashes
continuously on all connected
ports and the network is
disabled.
A network loop (redundant
path) has been created.
Break the loop by ensuring that there is only one
path from any networked device to any other
networked device.