Optoma EH505 User Guide - Page 23
Adjusting the horizontal image position, Lens Shift Range Diagram
View all Optoma EH505 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
Installation Adjusting the horizontal image position With the lens in the center position the horizontal image position can be adjusted to the left or right by up to a maximum of 5% of the image width. Please consult the Lens Shift Range diagram below for further clarification. Screen Width (W) Lens Shift Range Diagram H5% W5% H50% Left Side Right Side (W/2) x 10% (W/2) x 10% W W5% When W and H at 0% offset position The max. H up shift=Hx55% The max. H down shift=Hx15% The max. W shift=Wx5% When max. W shift is Wx5% Max. H shift=Hx50% When max. H shift is Hx55% Max. W shift=Hx0% H H15% WXGA / WUXGA W H5% W5% W5% H45% When W and H at 0% offset position The max. H up shift=Hx50% The max. H down shift=Hx10% The max. W shift=Wx5% When max. W shift is Wx5% Max. H shift=Hx45% When max. H shift is Hx50% Max. W shift=Hx0% H H10% XGA 23 English