Panasonic 26PSU1U6 Tech Data - Service Manual - Page 33
Control circuit fuse, Heat exchanger
View all Panasonic 26PSU1U6 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
1-2 Major Component Specifications (A) Indoor Unit MODEL No. Source Remote controller (Supplied / Optional) Controller P. C. B Ass'y Control circuit fuse Fan (Number ... diameter) Fan motor Model Source No. of pole ... r.p.m. (230 V, High) Nominal output Coil resistance (Ambient temperature 68 °F) in. (mm) rpm W Ω Safety device Operating temperature Run capacitor Heat exchanger Coil Rows ... Fins per inch Face area Open °F Close °F VAC, µF ft.2 (m2) 1. Specifications S-26PF1U6 230 - 208 V / 1 phase / 60 Hz Wired / Wireless (See Unit Specification) CR - TH2672 250 V, 5 A Centrifugal (4 ... 5-29/32(150)) KFG4X - 71B6P 230 - 208 V / 1 phase / 60 Hz 4 ... 920 100 BRW - WHT : 74.7 , ORG - YEL : 9.59 WHT - VLT : 19.1 , YEL - BLK : 10.52 VLT - ORG : 10.5 , BLK - PNK : 21.72 1 266 ± 14.4 174.2 ± 27 440 V , 5 µF Aluminum plate fin / Copper tube 3 ... 14.9 2.03 (0.189) DATA SUBJECT TO CHANGE WITHOUT NOTICE 1-27