Panasonic AW-SF100/SF200 AW-SF100 API Documentation - Page 6

Details of Commands

Page 6 highlights

Auto Tracking System Web API Specifications Version 1.6 3 Details of Commands 3.1 Camera Control The Camera Control command is used to start or stop communication with the target camera. The list of transmission parameters is as shown below. Name id control Table 3.1-1 List of Transmission Parameters Usage Type Description Mandatory Integer value This is the camera ID. Mandatory String Either start or stop is saved. The reception response parameter during communication with the camera is specified as below. message:[1] The information shown below is saved in [1]. No. Name 1 message Table 3.1-2 List of Values Type Description String In the case of a negative acknowledgment, the cause is saved as a message. Confidential © 2014-2015 Panasonic. All Rights Reserved. 6 of 24

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

Auto Tracking System Web API Specifications
Version 1.6
Confidential
© 2014-2015 Panasonic. All Rights Reserved.
6 of 24
3
Details of Commands
3.1
Camera Control
The Camera Control command is used to start or stop communication with the target camera. The list of
transmission parameters is as shown below.
Table 3.1-1 List of Transmission Parameters
Name
Usage
Type
Description
id
Mandatory
Integer
value
This is the camera ID.
control
Mandatory
String
Either start or stop is saved.
The reception response parameter during communication with the camera is specified as below.
message:[1]
The information shown below is saved in [1].
Table 3.1-2 List of Values
No.
Name
Type
Description
1
message
String
In the case of a negative acknowledgment, the cause is
saved as a message.