Pioneer 434CMX Service Manual - Page 79

COMMON-PANEL1, Function/Display, Content, Adjustable Range, Notes

Page 79 highlights

5 6 7 8 3. COMMON-PANEL1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 1 2 COMMON - P A N E L 1 I N 1 -G3 2 - RGB - 4MX A 3 4 5 6 7 8 9 10 11 12 13 14 15 X-SUS U1 < = > : 128 16 Each time the 5 or ∞ key is pressed, the subitems are changed, as follows: No. Corresponding 232C Command Function/Display 1 XU1 X-SUS U1 2 XU2 X-SUS U2 3 XD1 X-SUS D1 4 XD2 X-SUS D2 5 YU1 Y-SUS U1 6 YU2 Y-SUS U2 7 YD1 Y-SUS D1 8 YD2 Y-SUS D2 9 YD3 Y-SUS D3 10 YD4 Y-SUS D4 11 VSU VLT-SUS 12 VOF VLT-OFS Content Adjustment of X-SUS leading edge pulse U1 Adjustment of X-SUS leading edge pulse U2 Adjustment of X-SUS trailing edge pulse D1 Adjustment of X-SUS trailing edge pulse D2 Adjustment of Y-SUS leading edge pulse U1 Adjustment of Y-SUS leading edge pulse U2 Adjustment of Y-SUS trailing edge pulse D1 Adjustment of Y-SUS trailing edge pulse D2 Adjustment of X-SUS trailing edge pulse D3 Adjustment of X-SUS trailing edge pulse D4 SUS voltage adjustment OFFSET voltage adjustment B Adjustable Range 124 to 132 124 to 132 124 to 132 124 to 132 124 to 132 124 to 132 124 to 132 124 to 132 124 to 132 C 124 to 132 000 to 255 000 to 255 "∗∗∗" in the table above represents the adjustment value. The value of each subitem can be changed using the 2 or 3 key. Notes: • Adjustments No. 1 to No. 10 above are not normally required, unless so instructed by Service Information, etc. • Readjustment of values for No. 11 [VSU] and No. 12 [VOF] are required when the service panel is replaced. D E F PDP-434CMX 79 5 6 7 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153

PDP-434CMX
79
5
6
7
8
5
6
7
8
C
D
F
A
B
E
"
∗∗∗
" in the table above represents the adjustment value.
The value of each subitem can be changed using the
2
or
3
key.
3. COMMON-PANEL1
1
123456789
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
C
O
M
M
O
X
S
U
S
:
1
2
8
U
1
<
=
>
N
P
A
N
E
L
1
I
N
1
G
3
2
R
G
B
4
M
X
No.
Function/Display
Content
Adjustable Range
Corresponding 232C
Command
1
X-SUS U1 <=>
:
∗∗∗
Adjustment of X-SUS leading edge pulse U1
XU1
2
X-SUS U2 <=>
:
∗∗∗
Adjustment of X-SUS leading edge pulse U2
XU2
3
X-SUS D1 <=>
:
∗∗∗
Adjustment of X-SUS trailing edge pulse D1
XD1
4
X-SUS D2 <=>
:
∗∗∗
Adjustment of X-SUS trailing edge pulse D2
XD2
5
Y-SUS U1 <=>
:
∗∗∗
Adjustment of Y-SUS leading edge pulse U1
YU1
6
Y-SUS U2 <=>
:
∗∗∗
Adjustment of Y-SUS leading edge pulse U2
YU2
7
Y-SUS D1 <=>
:
∗∗∗
Adjustment of Y-SUS trailing edge pulse D1
YD1
8
Y-SUS D2 <=>
:
∗∗∗
Adjustment of Y-SUS trailing edge pulse D2
YD2
9
Y-SUS D3 <=>
:
∗∗∗
Adjustment of X-SUS trailing edge pulse D3
YD3
10
Y-SUS D4 <=>
:
∗∗∗
Adjustment of X-SUS trailing edge pulse D4
YD4
11
VLT-SUS <=>
:
∗∗∗
SUS voltage adjustment
VSU
12
VLT-OFS <=>
:
∗∗∗
OFFSET voltage adjustment
124 to 132
124 to 132
124 to 132
124 to 132
124 to 132
124 to 132
124 to 132
124 to 132
124 to 132
124 to 132
000 to 255
000 to 255
VOF
Each time the
5
or
key is pressed, the subitems are changed, as follows:
Notes:
• Adjustments No. 1 to No. 10 above are not normally required, unless so instructed by Service Information, etc.
• Readjustment of values for No. 11 [VSU] and No. 12 [VOF] are required when the service panel is replaced.