Pioneer DVL-909 Service Guide - Page 8
Disc Determination
View all Pioneer DVL-909 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
DV-505, DVL-909, DV-S9 1.2.5 Disc Determination Determination is achieved by checking the sine wave by sweeping the lens with the OE IC gain at L and the FSC error amplifier (SGC) at the default setting. If no sine wave is detected, checking is retried after switching the OE IC gain to H and increasing the gain of the FSC error amplifier (SGC). If no sine wave is detected again, it is regarded as the NO DISC condition. If one half of the sine wave detected at the first lens sweep is of a value less than 0.5 V, the OE IC gain is set to H and the peak-topeak value of the sine wave is roughly adjusted to 1.8 Vp-p. By sweeping the lens around the height where the sine wave has been detected, disc determination is performed, and the sine wave is finely adjusted to 1.8 Vp-p. Offset compensation Lens sweep Checking Yes the sine wave None OEIC gain = H FCS AMP gain up Lens sweep Level check Less than 0.5V More than 0.5V OEIC gain = H Checking Yes the sine wave None NO DISC Roughly adjust to 1.8Vp-p sine wave Disc determination Finely adjust to 1.8Vp-p sine wave END 8