ProForm Power 575i Instruction Manual - Page 30

Unplug The Power

Page 30 highlights

SYMPTOM: The walking belt is not centered between the foot rails a. IMPORTANT: If the walking belt rubs against the foot rails (B), the walking belt may become damaged. First, remove the key and UNPLUG THE POWER CORD. If the walking belt has shifted to the left, use the hex key to turn the left idler roller screw clockwise 1/2 of a turn; if the walking belt has shifted to the right, turn the left idler roller screw counterclockwise 1/2 of a turn. Be careful not to overtighten the walking belt. Then, plug in the power cord, insert the key, and walk on the treadmill for a few minutes. Repeat until the walking belt is centered. SYMPTOM: The tablet holder does not stay in place a. Rotate the tablet holder (C) until it faces backward. Then, tighten the indicated screw (D) slightly until the tablet holder stays in place when it is rotated to the desired position. a C D a B B SYMPTOM: The walking belt slips when walked on a. First, remove the key and UNPLUG THE POWER CORD. Using the hex key, turn both idler roller screws clockwise, 1/4 of a turn. When the walking belt is correctly tightened, you should be able to lift each edge of the walking belt 2 to 3 in. (5 to 7 cm) off the walking platform. Be careful to keep the walking belt centered. Then, plug in the power cord, insert the key, and walk on the treadmill for a few minutes. Repeat until the walking belt is properly tightened. a 30

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

30
SYMPTOM: The walking belt is not centered
between the foot rails
a.
IMPORTANT: If the walking belt rubs against
the foot rails (B), the walking belt may become
damaged.
First, remove the key and
UNPLUG
THE POWER CORD.
If the walking belt has
shifted to the left,
use the hex key to turn the
left idler roller screw clockwise 1/2 of a turn;
if the
walking belt has shifted to the right,
turn the
left idler roller screw counterclockwise 1/2 of a
turn. Be careful not to overtighten the walking belt.
Then, plug in the power cord, insert the key, and
walk on the treadmill for a few minutes. Repeat
until the walking belt is centered.
SYMPTOM: The walking belt slips when walked on
a.
First, remove the key and
UNPLUG THE POWER
CORD.
Using the hex key, turn both idler roller
screws clockwise, 1/4 of a turn. When the walk-
ing belt is correctly tightened, you should be able
to lift each edge of the walking belt 2 to 3 in. (5 to
7 cm) off the walking platform. Be careful to keep
the walking belt centered. Then, plug in the power
cord, insert the key, and walk on the treadmill for a
few minutes. Repeat until the walking belt is prop-
erly tightened.
SYMPTOM: The tablet holder does not stay in place
a.
Rotate the tablet holder (C) until it faces backward.
Then, tighten the indicated screw (D) slightly until
the tablet holder stays in place when it is rotated to
the desired position.
a
B
B
a
C
D
a