Samsung NX58R9311SS/AA Installation Guide - Page 16

To avoid breakage, English, DO

Page 16 highlights

Installation requirements Recommended locations for gas piping and electrical outlets (For model NX58*931***) Recommended position Optional rear filler kit WARNING Used to fill gap between the range back and wall. Adds a filler strip to the rear of the range. This kit can only be used when the opening in the countertop is 25" deep. NOTE If the countertop depth is greater than 25", there will be a gap between the filler kit and the back wall. 17 in x 9 in (43.2 cm x 22.9 cm) Gas Wall Area Recommended area for through-the-wall and through-the-floor connection of gas pipe stub and shut-off valve. 12 in (30.5 cm) Recommended area for 120V electrical outlet on rear wall 17(4Gi3na.2sxFc2mloion3xr0C5Aai.brn1ein(ac7me6t).O2pcemn)ing CAUTION You must use the rear filler kit to install the range in a freestanding cutout cabinet. For more information, see "Optional rear filler kit" as shown below. To avoid breakage CAUTION Please DO NOT push the unit strongly when you install. These actions can cause the damage to the unit. Please DO NOT push the burner knobs when installing the range. (Grasp the L/R door area to push the unit.) Installation requirements 16 English Install_NX58R9311SS_AA_DG68-00906B-00_EN+MES+CFR.indb 16 2019-06-03 2:18:16

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

16 English
Installation requirements
Installation requirements
Recommended locations for gas piping and electrical outlets
(For model NX58*931***)
Recommended area
for 120V electrical
outlet on rear wall
Recommended
position
30 in (76.2 cm)
Cabinet Opening
12 in
(30.5 cm)
17 in x 9 in
(43.2 cm x 22.9 cm)
Gas Wall Area
Recommended area
for through-the-wall
and through-the-floor
connection of gas pipe
stub and shut-off valve.
17 in x 2 in
(43.2 cm x 5.1 cm)
Gas Floor Area
CAUTION
You must use the rear filler kit to install the range in a freestanding cutout cabinet.
For more information, see “Optional rear filler kit” as shown below.
Optional rear filler kit
WARNING
Used to fill gap between the range back and wall. Adds a filler strip to the rear of
the range. This kit can only be used when the opening in the countertop is 25” deep.
NOTE
If the countertop depth is greater than 25”, there will be a gap between the filler
kit and the back wall.
To avoid breakage
CAUTION
Please
DO NOT
push the unit strongly when
you install. These actions can cause the
damage to the unit.
Please
DO NOT
push the burner knobs when
installing the range.
(Grasp the L/R door area to push the unit.)
Install_NX58R9311SS_AA_DG68-00906B-00_EN+MES+CFR.indb
16
2019-06-03
°° 2:18:16