Samsung SSC-1000 User Guide - Page 13

Confirmation Matter in Times of, Abnormality Occurrence, Specifications

Page 13 highlights

SSC-1000 (gb) 2009.1.8 1:38 PM Page 22 User's Guide 5. Confirmation Matter in Times of Abnormality Occurrence Symptom Confirmation and Management Matters Control of the camera part is not possible. 1. Check the polarity of the RS-485 indication line. 2. Check if the address of the camera part has been set up well. The input channel number of the Matrix Switcher and the number of the camera part appear differently. Set up the address number of the camera part and the input channel number of the Matrix Switcher to be the same. Because I cannot remember the Password of this machine, I cannot enter the set-up MENU. In the state in which the RESET button has been pressed, if you put in again the power, the machine gets into the state freshly out of the plant, and you can go into the set-up menu. ❈ The contents and the circuits in this explanation can be changed due to such reasons as the functional improvement of the production. 22 6. Specifications ITEM Communication Interface Type Port Connector Type Baud Rate SPECIFICATION RS-485 Modular Type x2, D-SUB x1 1200, 2400, 4800, 9600, 19200, 38400 BPS PROTOCOL SAMSUNG, PELCO-D, PELCO-P, VICON PANASONIC, KALATEL, DIAMOND, AD, PHILIPS,ERNA, VCL TP, TECHWIN Display LCD LED 20 ✕ 4 line MENU, PRESET, PATTERN, SCAN, AUTO PAN, RESET Switching Video Switching SEQUENCE, TOUR, SALVO & Pan/Tilt & Lens Pan left/right Control Control Tilt up/down Iris open/close Focus far/near Zoom tele/wide Preset, Auto pan, Scan, Pattern External AUX1, AUX2, AUX3, AUX4 machinery Control Power Source DC 9V 600mA Dimension 315(W) ✕ 205(D) ✕ 65(H)mm Weight 1.1kg (Excluding packaged goods) RS-485 Connector No 3 (Yellow) : DATA "+", No 5(Red) : DATA "-" D-SUB Connector No 2 : DATA "+", No 3 : DATA "-" 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13

23
User’s Guide
22
5. Confirmation Matter in Times of
Abnormality Occurrence
Symptom
Confirmation and Management Matters
Control of the camera
1. Check the polarity of the RS-485 indication
part is not possible.
line.
2. Check if the address of the camera part has
been set up well.
The input channel number
Set up the address number of the camera
of the Matrix Switcher
part and the input channel number of the
and the number of the
Matrix Switcher to be the same.
camera part appear differently.
Because I cannot remember
In the state in which the RESET button has
the Password of this
been pressed, if you put in again the power,
machine, I cannot enter
the machine gets into the state freshly out of
the set-up MENU.
the plant, and you can go into the set-up menu.
The contents and the circuits in this explanation can be changed due to
such reasons as the functional improvement of the production.
6. Specifications
ITEM
SPECIFICATION
Communication
Interface Type
RS-485
Port
Connector Type
Modular Type x2, D-SUB x1
Baud Rate
1200, 2400, 4800, 9600, 19200, 38400 BPS
SAMSUNG, PELCO-D, PELCO-P, VICON
PROTOCOL
PANASONIC, KALATEL, DIAMOND,
AD, PHILIPS,ERNA, VCL TP, TECHWIN
Display
LCD
20
4 line
LED
MENU, PRESET, PATTERN, SCAN,
AUTO PAN, RESET
Switching
Video Switching
SEQUENCE, TOUR, SALVO
&
Pan/Tilt & Lens
Pan left/right
Control
Control
Tilt up/down
Iris open/close
Focus far/near
Zoom tele/wide
Preset, Auto pan, Scan, Pattern
External
AUX1, AUX2, AUX3, AUX4
machinery Control
Power Source
DC 9V 600mA
Dimension
315(W)
205(D)
65(H)mm
Weight
1.1kg (Excluding packaged goods)
RS-485 Connector
No 3 (Yellow) : DATA “+”,
No 5(Red) : DATA “–”
D-SUB Connector
No 2 : DATA “+”, No 3 : DATA “–”
SSC-1000 (gb)
2009.1.8
1:38 PM
Page 22