Seagate ST340015A Product Manual - Page 25

Barracuda 5400.1 Product Manual, Rev. F, Electromagnetic immunity, Reliability

Page 25 highlights

Barracuda 5400.1 Product Manual, Rev. F 17 2.12 Electromagnetic immunity When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table: Test Description Performance Reference level standard Electrostatic Contact, HCP, VCP: ± 4 kV; B discharge Air: ± 8 kV Radiated RF immunity 80 to 1,000 MHz, 3 V/m, A 80% AM with 1 kHz sine 900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz Electrical fast ± 1 kV on AC mains, ± 0.5 B transient kV on external I/O Surge immunity ± 1 kV differential, ± 2 kV B common, AC mains Conducted 150 kHz to 80 MHz, 3 Vrms, A RF immunity 80% AM with 1 kHz sine Voltage dips, 0% open, 5 seconds C interrupts 0% short, 5 seconds C 40%, 0.10 seconds C 70%, 0.01 seconds B EN 61000-4-2: 95 EN 61000-4-3: 96 ENV 50204: 95 EN 61000-4-4: 95 EN 61000-4-5: 95 EN 61000-4-6: 97 EN 61000-4-11: 94 2.13 Reliability Nonrecoverable read errors 1 per 1014 bits read, max. Mean time between failures 600,000 power-on hours . (nominal power, 25°C ambient temperature) Service life The drive shall have a useful service life of five years. Contact start-stop cycles 50,000 cycles. (at nominal voltage and temperature, with 60 cycles per hour and a 50% duty cycle) Preventive maintenance None required.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58

Barracuda 5400.1 Product Manual, Rev. F
17
2.12
Electromagnetic immunity
When properly installed in a representative host system, the drive operates
without errors or degradation in performance when subjected to the radio
frequency (RF) environments defined in the following table:
2.13
Reliability
Test
Description
Performance
level
Reference
standard
Electrostatic
discharge
Contact, HCP, VCP:
±
4
kV;
Air:
±
8 kV
B
EN 61000-4-2: 95
Radiated RF
immunity
80 to 1,000 MHz, 3 V/m,
80% AM with 1 kHz sine
900 MHz, 3 V/m, 50% pulse
modulation @ 200 Hz
A
EN 61000-4-3: 96
ENV 50204: 95
Electrical fast
transient
±
1 kV on AC mains,
±
0.5
kV on external I/O
B
EN 61000-4-4: 95
Surge
immunity
±
1 kV differential,
±
2 kV
common, AC mains
B
EN 61000-4-5: 95
Conducted
RF immunity
150 kHz to 80 MHz, 3 Vrms,
80% AM with 1 kHz sine
A
EN 61000-4-6: 97
Voltage dips,
interrupts
0% open, 5 seconds
0% short, 5 seconds
40%, 0.10 seconds
70%, 0.01 seconds
C
C
C
B
EN 61000-4-11: 94
Nonrecoverable read errors
1 per 10
14
bits read, max.
Mean time between failures
600,000 power-on hours .
(nominal power, 25°C ambient temperature)
Service life
The drive shall have a useful service life of five years.
Contact start-stop cycles
50,000 cycles.
(at nominal voltage and temperature, with 60 cycles
per hour and a 50% duty cycle)
Preventive maintenance
None required.