Seiko SUP433 Owner Manual - Page 6
Guideline Of Charging Time/accuracy
View all Seiko SUP433 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
GUIDELINE OF CHARGING TIME/ACCURACY English V110 V111/ V117 Environment/Lightsource (lux) A (minutes) B (hours) C (hours) A (minutes) B (hours) C (hours) General offices/ Fluorescent light (700) 50 16 140 180 60 - 30W20cm/ Fluorescent light (3000) 11 3.5 30 35 10 180 Cloudy weather/Sunlight (10000) 3 0.9 8 12 4 60 Fair weather/Sunlight (100000) 1 0.3 2 2 0.5 10 Expected life per charge from full charge to stoppage 5 months 6 months Loss/gain (monthly rate) Less than 20 seconds when the watch Less than 15 seconds when the watch is worn on your wrist at a normal is worn on your wrist at a normal temperature range (5 ºC to 35 ºC) temperature range (5 ºC to 35 ºC) Operational temperature range -5 ºC to 50 ºC -10 ºC to 60 ºC A: Time to charge 1 day of power B: Time required for steady operation C: Time required for full charge 10 V114 / V115 / V116 V137 V147/ V157/ V158 A (minutes) B (hours) C (hours) A (minutes) B (hours) C (hours) A (minutes) B (hours) C (hours) 180 60 - 110 16 - 110 25 - 35 10 180 30 4 90 30 6 120 12 4 60 8 1.2 30 10 2 35 2 0.5 10 1 0.1 10 2 0.4 9 12 months 6 months 10 months Less than 15 seconds when the watch is worn on your wrist at a normal temperature range (5 ºC to 35 ºC) -10 ºC to 60 ºC v The above table provides only a general guideline. 11 English