Sharp AF-08CRL Service Manual - Page 16
Disassembling Procedure
View all Sharp AF-08CRL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
AF-08CRL DISASSEMBLING PROCEDURE CAUTION: DISCONNECT THE ROOM AIR CONDITIONER FROM THE POWER SUPPLY BEFORE ANY SERVICE 1. Unscrew the 2 screws holding the front panel on each 5. Remove the control panel. side. 2. Remove the front panel by pulling the front panel at the 6. Take off the fan motor connector. lower corner toward you about one inch. Next lift up and pull it toward you. 3. Unscrew the 8 screws holding the cabinet. 2 screws are on each side. 4 screws are on back side. 2 screws are on top side. And remove the cabinet. 7. Unscrew the 5 screws. 3 screws are holding the control box at the top and right side. 1 screw is holding the power supply cord. 1 screw each screw on the evaporator. 4. Remove the thermistor holder. 8. Cut the wire fixing band, slide the control box rightward and remove. Slide 16