Sharp AF-08CRL Service Manual - Page 16

Disassembling Procedure

Page 16 highlights

AF-08CRL DISASSEMBLING PROCEDURE CAUTION: DISCONNECT THE ROOM AIR CONDITIONER FROM THE POWER SUPPLY BEFORE ANY SERVICE 1. Unscrew the 2 screws holding the front panel on each 5. Remove the control panel. side. 2. Remove the front panel by pulling the front panel at the 6. Take off the fan motor connector. lower corner toward you about one inch. Next lift up and pull it toward you. 3. Unscrew the 8 screws holding the cabinet. 2 screws are on each side. 4 screws are on back side. 2 screws are on top side. And remove the cabinet. 7. Unscrew the 5 screws. 3 screws are holding the control box at the top and right side. 1 screw is holding the power supply cord. 1 screw each screw on the evaporator. 4. Remove the thermistor holder. 8. Cut the wire fixing band, slide the control box rightward and remove. Slide 16

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

16
AF-08CRL
1.
Unscrew the 2 screws holding the front panel on each
side.
DISASSEMBLING PROCEDURE
CAUTION: DISCONNECT THE ROOM AIR CONDITIONER FROM THE POWER SUPPLY BEFORE ANY
SERVICE
2.
Remove the front panel by pulling the front panel at the
lower corner toward you about one inch.
Next lift up and pull it toward you.
5.
Remove the control panel.
6.
Take off the fan motor connector.
4.
Remove the thermistor holder.
7.
Unscrew the 5 screws.
3 screws are holding the control box at the top and
right side.
1 screw is holding the power supply cord.
1 screw each screw on the evaporator.
3.
Unscrew the 8 screws holding the cabinet.
2 screws are on each side.
4 screws are on back side.
2 screws are on top side.
And remove the cabinet.
8.
Cut the wire fixing band, slide the control box rightward
and remove.
Slide