Sharp AF-08CRL Service Manual - Page 23
Table Y-3, Safety start, Test mode, Table Y-2
View all Sharp AF-08CRL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
AF-08CRL 6. Safety start When you turn the air conditioner OFF and restart again soon, wait at least 3 minutes before the cooling operation starts. 7. Test mode Keep pushing both buttons "POWER ON/OFF" and " " " and supply the power, the system will go to the test mode. In this mode, the output operation is switched by pushing buttons. Normal outputs are shown in Table Y-2. For selfdiagnosis check mode Table Y-2 No. PUSH KEY (SWITCH) 0 PLUG IN the power supply cord while pushing power ON/OFF key and (down) key. 1 SELECTOR BEPP LED1 LED LIGHTING CHECK ITEM SOUND FAN FAN FAN COOL FAN TIMER ENERGY POWER FAN COMP and REMARK HIGH MID LOW SAVER ON/OFF OUTPUT OUTPUT 2 8.8 ON ON ON ON ON ON ON ON OFF O F F LED ALL ON 1 OFF OFF OFF OFF OFF OFF OFF OFF OFF LOW O F F LED ALL OFF 2 1 01 OFF OFF OFF OFF OFF OFF OFF 1) MIDDLE O F F 2) 3) 4) 3 1 02 ON OFF OFF ON OFF OFF ON OFF HIGH O F F FAN CHECK 4 TIMER 1 03 OFF ON OFF OFF ON OFF OFF ON OFF O F F 5 ENERGY SAVER 1 04 OFF OFF ON OFF OFF ON OFF OFF LOW O F F 6 ON/OFF 1 05 ON OFF OFF ON OFF OFF ON OFF HIGH O N COMPRESSOR CHECK 7 POWER ON/OFF by REMOTE CONTROL 1 05 OFF OFF OFF OFF OFF OFF OFF OFF MIDDLE O F F REMOTE CONTROL CHECK 8 POWER SUPPLY OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF O F F 1) If thermistor is normal (nether short nor open), LED is ON. 2) When A/D (R42) bit 7 = 1, LED is ON. 2) When A/D (R42) bit 6 = 1, LED is ON. 2) When A/D (R42) bit 5 = 1, LED is ON. T(˚C) 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 T(˚F) 32.0 33.8 35.6 37.4 39.2 41.0 42.8 44.6 46.4 48.2 50.0 51.8 53.6 55.4 57.2 59.0 60.8 62.8 64.4 66.2 68.0 R(kΩ) 49.33 46.86 44.53 42.33 40.25 38.29 36.44 34.68 33.02 31.45 29.96 28.55 27.22 25.96 24.76 23.62 22.56 21.52 20.55 19.63 18.76 Table Y-3 V(volts) 1.17 1.21 1.26 1.31 1.36 1.41 1.46 1.51 1.56 1.61 1.67 1.72 1.78 1.83 1.89 1.94 2.00 2.05 2.11 2.17 2.22 T(˚C) 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 T(˚F) 69.8 71.6 73.4 75.2 77.0 78.8 80.6 82.4 84.2 86.0 87.8 89.6 91.4 93.2 95.0 96.8 98.6 100.4 102.2 104.0 R(kΩ) 17.93 17.14 16.39 15.68 15.00 14.36 13.74 13.16 12.60 12.07 11.57 11.09 10.63 10.19 9.78 9.38 9.00 8.64 8.30 7.97 V(volts) 2.28 2.33 2.39 2.44 2.50 2.55 2.61 2.66 2.71 2.77 2.82 2.87 2.93 2.98 3.03 3.08 3.13 3.17 3.22 3.27 V ....... Input the voltage of microcomputer (No. 10-port). 23