Sharp AF-08CRL Service Manual - Page 2
Specifications - model
View all Sharp AF-08CRL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
AF-08CRL SPECIFICATIONS Models Cooling capacity Moisture removal BTU/h Pints/h AF-08CRL 8000 2.3 ELECTRICAL DATA Phase Rared frequency Rated voltage Rated current Rated input Power factor EER Hz Volts Amps Watts % BTU/Wh Single 60 115 7.3 800 95 10.0 COMPRESSOR Type Model, Motor output (Hermetically sealed rotary type) 2R12S3R126A-6A, 600W REFRIGERANT SYSTEM Evaporator Condenser Control O.D. x I.D. x Length x Q'ty(mm) (Capillary tube) Refrigerant volume R-22(OZ) (Factory change) Louver fin, Grooved tube, 7mm, Hair pin Louver fin, Grooved tube, 7mm, Hair pin 2.7 x 1.2 x 450 x 1 15.9 NET DIMENSIONS Width Height Depth Net Weight inches(mm) 19-11/16(500) x 14-9/16(370) x 17-3/32(434) lbs 53 GROSS DIMENSIONS Width Height Depth Gross Weight inches(mm) lbs 22-27/32(580) x 18-5/16(465) x 19-31/32(507) 60 FAN SYSTEM Indoor side(Evaporator) Outdoor side(Condenser) Air flow rate(indoor side) CFM Centrifugal fan Propeller fan High / Med / Low 187 / 173 / 155 OTHERS Safety devices Air filter Power cord length ft Power plug type Compressor: Overload relay Fan motor: Internal thermal protector Polypropylene net 6.0 125V, 10A 2