Sharp AF-08CRL Service Manual - Page 18

Disassembling The Control Box

Page 18 highlights

AF-08CRL 17. Unscrew the 1 screw holding the centrifugal fan. 18. Unscrew the 3 screws holding fan motor. DISASSEMBLING THE CONTROL BOX 1. Unscrew the 1 screw holding the control box cover. CAUTION: DISCHARGE THE FAN MOTOR CAPACITOR AND RUNNING CAPACITOR BEFORE TOUCHING THOSE CAPACITORS OR OTHER COMPONENTS OR WIRING. 4. Unscrew the 1 power supply cord grounding screw. Unscrew the earth screw. Unscrew the 1 screw holding the capacitor clamp and the fan motor capacitor. 2. Unscrew the 3 screws holding the printed wiring board. 5. Detach each connector by using long-noise pliers. 3. Cut the wire fixing bands holding the fan motor lead 6. Unscrews the 2 screws holding the transformer and wires, the compressor cord and the power supply cord. remove the control board with unhooking the 2 spacers. 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

18
AF-08CRL
17. Unscrew the 1 screw holding the centrifugal fan.
18. Unscrew the 3 screws holding fan motor.
DISASSEMBLING THE CONTROL BOX
1.
Unscrew the 1 screw holding the control box cover.
CAUTION: DISCHARGE THE FAN MOTOR CAPACITOR
AND RUNNING CAPACITOR BEFORE
TOUCHING THOSE CAPACITORS OR OTHER
COMPONENTS OR WIRING.
4.
Unscrew the 1 power supply cord grounding screw.
Unscrew the earth screw. Unscrew the 1 screw holding
the capacitor clamp and the fan motor capacitor.
2.
Unscrew the 3 screws holding the printed wiring board.
5.
Detach each connector by using long-noise pliers.
6.
Unscrews the 2 screws holding the transformer and
remove the control board with unhooking the 2 spacers.
3.
Cut the wire fixing bands holding the fan
motor lead
wires, the compressor cord and the power supply cord.