Sony BVMF170A User Manual (Operating Instructions - BVM-F250A / BVM-F170A) - Page 53

Internal], External, Auto Adjust, To cancel/stop the adjustment, Select Auto Adjust.

Page 53 highlights

Chapter 3 Menu Color Temp Adj Menu Signal Contrast/Bright Hold Auto (for BVM-F170A only) Auto Adjust Target Color Temp x y Target Luminance Contrast/Bright Hold Copy From Function and operation ([ ]: factory setting) Sets the white signal to be used for adjustment. [Internal]: Select when an internal signal is used. The signal is automatically switched in synchronization with the gain and bias adjustments. External: Select when an external input signal is used. Supply a signal to be used when adjusting gain and bias. Sets the contrast and brightness to the adjusted value or the center value. Off: Sets contrast and brightness to the center values during and after color temperature adjustment. [On]: Retains the adjusted contrast and brightness values during and after color temperature adjustment. Adjusts the color temperature automatically using the built-in color sensor. When this item is selected, the color temperature data to be adjusted is displayed. When D93 or D65 data is changed, they are displayed as D93* or D65*. When Contrast/Bright Hold is set to Off, the color temperature data are displayed. The contrast data is displayed as the picture preset data Preset1 to Preset5 set in the Picture Preset menu of the Channel Configuration menu. To change the type of the picture preset data, select from Preset1 to Preset5 in the Picture Preset menu (page 58) of the Channel Configuration menu. Starts adjustment. When Auto Adjust is selected, not only the target color temperature but also other color temperature data are adjusted. Before automatic adjustment, select the value to use for the adjustment in following sequence. When you use the previously adjusted values for adjustment, select Auto Adjust in step 3 to start adjustment without performing step 1 and step 2. 1 Select the color temperature to be used in Target Color Temp. When Any is selected, enter the values of the CIE color system x and y coordinates. 2 Select Target Luminance and enter the value of the luminance (cd/m2) when the 100% white signal is input. 3 Select Auto Adjust. The cursor appears and flashes at the bottom left of the screen. (It may take some time until the automatic adjustment is completed.) To cancel/stop the adjustment Press the MENU button. Sets the adjustment value to be used from D93, D65 or Any. Enters the CIE color system x coordinate. Set to 0.265 to 0.350. Enters the CIE color system y coordinate. Set to 0.270 to 0.360. Enters the luminance (cd/m2) when the 100% white signal is input with the contrast and brightness set to the center. You can enter the value between 40 and 150. [100] Note The calibrated luminance does not guarantee an absolute value and may be different from the luminance detected by the probe. Sets the contrast and brightness to the adjusted value or the center value. The contrast value is fixed to 1000, and the brightness value is fixed to 000 during the automatic adjustment. Off: The contrast and brightness values are retained at the center value even after color temperature adjustment. [On]: The contrast and brightness values are returned to the previous values before color temperature adjustment. Copies the other color temperature. Note Use the controller with software version 1.6 or higher to use the Copy From function. 53 Adjustment Menu

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140

53
Adjustment Menu
Chapter 3
Menu
Color Temp Adj
Signal
Sets the white signal to be used for adjustment.
[Internal]:
Select when an internal signal is used.
The signal is automatically switched
in synchronization with the gain and bias adjustments.
External:
Select when an external input signal is used.
Supply a signal to be used when
adjusting gain and bias.
Contrast/Bright Hold
Sets the contrast and brightness to the adjusted value or the center value.
Off:
Sets contrast and brightness to the center values during and after color temperature
adjustment.
[On]:
Retains the adjusted contrast and brightness values during and after color
temperature adjustment.
Auto (for BVM-F170A only)
Adjusts the color temperature automatically using the built-in color sensor.
When this item is selected, the color temperature data to be adjusted is displayed.
When D93 or D65 data is changed, they are displayed as D93* or D65*.
When Contrast/Bright Hold is set to Off, the color temperature data are displayed.
The
contrast data is displayed as the picture preset data Preset1 to Preset5 set in the Picture
Preset menu of the Channel Configuration menu. To change the type of the picture preset
data, select from Preset1 to Preset5 in the Picture Preset menu (page 58) of the Channel
Configuration menu.
Auto Adjust
Starts adjustment.
When Auto Adjust is selected, not only the target color temperature but also other color
temperature data are adjusted.
Before automatic adjustment, select the value to use for the adjustment in following
sequence.
When you use the previously adjusted values for adjustment, select
Auto Adjust
in step
3
to
start adjustment without performing step
1
and step
2
.
1
Select the color temperature to be used in Target Color Temp.
When Any is selected, enter the values of the CIE color system x and y coordinates.
2
Select Target Luminance and enter the value of the luminance (cd/m
2
) when the
100% white signal is input.
3
Select Auto Adjust.
The cursor appears and flashes at the bottom left of the screen.
(It may take some time until the automatic adjustment is completed.)
To cancel/stop the adjustment
Press the MENU button.
Target Color Temp
Sets the adjustment value to be used from
D93
,
D65
or
Any
.
x
Enters the CIE color system x coordinate.
Set to
0.265
to
0.350
.
y
Enters the CIE color system y coordinate.
Set to
0.270
to
0.360
.
Target Luminance
Enters the luminance (cd/m
2
) when the 100% white signal is input with the contrast and
brightness set to the center.
You can enter the value between
40
and
150
.
[100]
Note
The calibrated luminance does not guarantee an absolute value and may be different from
the luminance detected by the probe.
Contrast/Bright Hold
Sets the contrast and brightness to the adjusted value or the center value.
The contrast value is fixed to 1000, and the brightness value is fixed to 000 during the
automatic adjustment.
Off:
The contrast and brightness values are retained at the center value even after color
temperature adjustment.
[On]:
The contrast and brightness values are returned to the previous values before
color temperature adjustment.
Copy From
Copies the other color temperature.
Note
Use the controller with software version 1.6 or higher to use the Copy From function.
Menu
Function and operation ([
]: factory setting)