Thermador VCIN36JP User Manual - Page 10

Lights, Heat Sensor

Page 10 highlights

Lights This button controls the halogen lighting. The first press turns the lights on. A second press dims the lights. A third press turns the lights off. 1 - ON 2 - DIM 3 - OFF Heat Sensor (custom insert control panel only) Heat sensor feature is disabled if a remote control is installed. Over-temperature Condition The high temperature sensor protects the hood from high temperatures which may damage components. The control is set to activate at 161 °F (72 °C) and reset at 140 °F (60 °C). When activated, the blower will turn on low and the corresponding LED will blink, indicating an overtemperature condition. While the high temperature sensor is activated, the blower speed can be changed or turned off. If the blower is turned off, the corresponding LED will blink. Light controls will remain operational. When the control sensor reaches 140°F (60°C), a reset will occur. During reset, the control will revert back to the operational state prior to the high temperature condition. High Temperature Fault Condition The circuit is equipped with an alarm indicating that the heat sensor protection is not working due to a damaged sensor. In the case of this extreme condition, the three fan speed indicator LEDs will start blinking. All the controls will be operational except for the speed indicators. English 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38

English 5
Lights
This button controls the halogen lighting. The first press
turns the lights on. A second press dims the lights. A third
press turns the lights off.
1 — ON
2 — DIM
3 — OFF
Heat Sensor
(custom insert control panel only)
Heat sensor feature is disabled if a remote control is
installed.
Over-temperature Condition
The high temperature sensor protects the hood from high
temperatures which may damage components. The control
is set to activate at 161 °F (72 °C) and reset at 140 °F
(60 °C). When activated, the blower will turn on low and the
corresponding LED will blink, indicating an over-
temperature condition.
While the high temperature sensor is activated, the blower
speed can be changed or turned off. If the blower is turned
off, the corresponding LED will blink. Light controls will
remain operational. When the control sensor reaches
140°F (60°C), a reset will occur. During reset, the control
will revert back to the operational state prior to the high
temperature condition.
High Temperature Fault Condition
The circuit is equipped with an alarm indicating that the
heat sensor protection is not working due to a damaged
sensor. In the case of this extreme condition, the three fan
speed indicator LEDs will start blinking. All the controls will
be operational except for the speed indicators.