Page 91 highlights
MOBILE COMMUNICATIONS DIVISION CUSTOMER SERVICES 7.1.13 CAMERA FAULTY Cause: PCB dead or CMOS has broken Camera Testing Restore factory setting Fail Re-Download No Yes Refer to (Updating program is failed) Check CMOS FPC and (J401)PCBA being connected OK ? Yes Check Camera module being OK No Repair ACF CMOS FPC No (1) Repair ACF CMOS FPC (2)change Camera module Yes PCBA dead Version 1.0 22/11/2006 Created by Konrad Szombara Page 91 of 103
MOBILE COMMUNICATIONS DIVISION
CUSTOMER SERVICES
Version 1.0 22/11/2006
Created by Konrad Szombara
Page 91 of 103
7.1.13 CAMERA FAULTY
Cause: PCB dead or CMOS has broken
Camera
Testing
Restore factory setting
Re-Download
Refer to (Updating program is failed)
Fail
No
Yes
Check
CMOS FPC and (J401)PCBA being
connected OK ?
Repair ACF CMOS FPC
Check
Camera module being OK
(1) Repair ACF CMOS FPC
(2)change Camera module
PCBA dead
Yes
Yes
No
No