Quick Installation Note! Although some installation procedures are common to all models, some procedures vary depending on whether you are installing a SmartPro model or an OmniSmart model. 1 F or All Models-Plug your UPS into a 3-wire grounded, 120V AC, 60 Hz utility outlet. Note: UL 60601-1 listed UPS systems only meet UL standard 60601-1 for medical equipment when plugged into a hospital-grade outlet. For SmartPro Models Only: After you plug the UPS into a live AC outlet, the UPS will automatically charge its batteries, but will not sup- 1 ply power to its outlets until it is turned ON (see Step 3 below). The BATTERY CHARGE LED will be the only LED illuminated. For OmniSmart Models Only: Your UPS will run a self-test after it is plugged in. See Basic Operation to understand the results of its self-test. 2 F or All Models-Plug your equipment into the UPS.* * Your UPS is designed to only support computer equipment. You will overload the UPS if the total VA ratings for all the equipment you connect exceeds the UPS's Output Capacity (see Specifications). To find your equipment's VA ratings, look on their nameplates. If the equipment is listed in amps, multiply the number of amps by 120 to determine VA. (Example: 1 amp × 120 = 120 VA). If you are unsure if you have overloaded the UPS's outlets, see "OUTPUT LOAD LEVEL" LED description. 2 3 F or SmartPro Models Only-Turn the UPS ON. Press and hold the "POWER" button for one second. The alarm will beep once briefly after one second has passed. Release the button. For OmniSmart Models Only- Select UPS Operating Mode.* Press the UPS/STANDBY button to toggle your UPS 3 between the UPS ("POWER" LED lit) and the STANDBY ("POWER" LED flashing) modes. Choose the operating mode based on your location: USA, Canada & Western Europe: • Leave the UPS in the UPS mode at all times. All Other Countries: • Put the UPS in the STANDBY mode when you are not using connected equipment. (WARNING! When set to "CHARGE ONLY," the UPS will not provide battery backup during a blackout or brownout.) • Put the UPS in the UPS mode when you are using connected equipment. *See Basic Operation section for a complete explanation of each mode. 3 200903087 93-2890.indb 3 3/26/2009 4:56:27 PM

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

3
Quick Installation
Note! Although some installation procedures are common to all models, some procedures vary depending
on whether you are installing a SmartPro model or an OmniSmart model.
1
For All Models—Plug your UPS
into a 3-wire grounded, 120V AC,
60 Hz utility outlet.
Note: UL 60601-1 listed UPS systems only meet UL standard
60601-1 for medical equipment when plugged into a hospital-grade
outlet.
For SmartPro Models Only:
After you plug the UPS into a live AC outlet, the UPS
will automatically charge its batteries, but will not sup-
ply power to its outlets until it is turned ON (see Step 3
below). The BATTERY CHARGE LED will be the only
LED illuminated.
For OmniSmart Models Only:
Your UPS will run a self-test after it is plugged in. See
Basic Operation to understand the results of its self-test.
2
For All Models—Plug your
equipment into the UPS.*
* Your UPS is designed to only support computer equipment. You
will overload the UPS if the total VA ratings for all the equipment
you connect exceeds the UPS’s Output Capacity (see Specifications).
To find your equipment’s VA ratings, look on their nameplates. If the
equipment is listed in amps, multiply the number of amps by 120 to
determine VA. (Example: 1 amp × 120 = 120 VA). If you are unsure
if you have overloaded the UPS’s outlets, see “OUTPUT LOAD
LEVEL” LED description.
3
For SmartPro Models Only—Turn
the UPS ON.
Press and hold the “POWER” button for one second.
The alarm will beep once briefly after one second has
passed. Release the button.
For OmniSmart Models Only—
Select UPS Operating Mode.*
Press the UPS/STANDBY button to toggle your UPS
between the UPS (“POWER” LED lit) and the
STANDBY (“POWER” LED flashing) modes. Choose
the operating mode based on your location:
USA, Canada & Western Europe:
• Leave the UPS in the UPS mode at all times.
All Other Countries:
• Put the UPS in the STANDBY mode when you are not
using connected equipment.
(WARNING! When set to “CHARGE ONLY,” the UPS will not pro-
vide battery backup during a blackout or brownout.)
• Put the UPS in the UPS mode when you are using
connected equipment.
*See Basic Operation section for a complete explanation of each
mode.
1
2
3