Menu Option Lamp Settings Description Lamp Mode ͫͫ Normal: Provides full lamp brightness. ͫͫ Eco: Reduces lamp power consumption by 20% (PG701WU)/30% (PG706WU/PG706HD) and lowers brightness to extend the lamp life and decreases the fan noise. ͫͫ Dynamic Eco: Reduces lamp power consumption by up to 30% (PG701WU)/65% (PG706WU/PG706HD) depending on the content brightness level. ͫͫ SuperEco+: Reduces lamp power consumption by 60% and lowers brightness to extend the lamp life and decreases the fan noise. NOTE: To control the lamp temperature, Eco Mode will be switched on for 10 minutes in every 4 hours when the Lamp Mode is set as SuperEco+. Reset Lamp Hours Resets the lamp timer after new lamp is installed. For changing the lamp, please contact qualified service personnel. Lamp Hours Information ͫͫ Lamp Usage Time: Displays the number of hours the lamp has been used. ͫͫ Equivalent Lamp Hour: Displays the overall lamp life. The method of calculating the equivalent light source hour is as follows: PG701WU: Total (equivalent) Lamp Hour = 4 x (hours used in Normal mode) + 2 x (hours used in Eco mode) + 1.67 x (hours used in Dynamic Eco mode) + 1 x (hours used in SuperEco+ mode) PG706WU/PG706HD: Total (equivalent) Lamp Hour = 5 x (hours used in Normal mode) + 2 x (hours used in Eco mode) + 1.67 x (hours used in Dynamic Eco mode) + 1 x (hours used in SuperEco+ mode) 70

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108

70
Menu Option
Description
Lamp Settings
Lamp Mode
ͫ
Normal: Provides full lamp brightness.
ͫ
Eco: Reduces lamp power consump°on by 20%
(PG701WU)/30% (PG706WU/PG706HD) and lowers
brightness to extend the lamp life and decreases the fan
noise.
ͫ
Dynamic Eco: Reduces lamp power consump°on by up to
30% (PG701WU)/65% (PG706WU/PG706HD) depending
on the content brightness level.
ͫ
SuperEco+: Reduces lamp power consump°on by 60%
and lowers brightness to extend the lamp life and
decreases the fan noise.
NOT±:
To control the lamp temperature, Eco Mode will be
switched on for 10 minutes in every 4 hours when the
Lamp Mode is set as SuperEco+.
Reset Lamp Hours
Resets the lamp timer after new lamp is installed. For changing
the lamp, please contact qualified service personnel.
Lamp Hours Information
ͫ
Lamp Usage Time:
Displays the number of hours the
lamp has been used.
ͫ
Equivalent Lamp Hour: Displays the overall lamp life. The
method of calcula°ng the equivalent light source hour is
as follows:
PG701WU
:
Total (equivalent) Lamp Hour = 4 x (hours used in
Normal mode) + 2 x (hours used in Eco mode) + 1.67 x
(hours used in Dynamic Eco mode) + 1 x (hours used in
SuperEco+ mode)
PG706WU/PG706HD
:
Total (equivalent) Lamp Hour = 5 x (hours used in
Normal mode) + 2 x (hours used in Eco mode) + 1.67 x
(hours used in Dynamic Eco mode) + 1 x (hours used in
SuperEco+ mode)