366 Appendix C: MIDI 2.12.3.24 Parameter change (Function call: pair, copy) Reception This is received if [Parameter change RX] is ON and the [Rx CH] matches the device number included in the SUB STATUS. This is echoed if [Parameter change ECHO] is ON. When this is received, pairing will be enabled/disabled for the specified channel. STATUS ID No. SUB STATUS GROUP ID MODEL ID ADDRESS DATA EOX 11110000 F0 01000011 43 0001nnnn 1n 00111110 3E 01111111 7F 00010001 11 0000ffff 0f 0sssssss sh 0sssssss sl 0ddddddd dh 0ddddddd dl 11110111 F7 System exclusive message Manufacture's ID number (YAMAHA) n=0-15 (Device number=MIDI Channel) MODEL ID (digital mixer) Universal Function call Pair function Source channel H Source channel L Destination channel H Destination channel L End of exclusive function PAIR ON with COPY PAIR ON with RESET BOTH PAIR OFF 0x00 *1) 0x01 *1) 0x02 *1) channel *1) 0:CH1 - 47:CH48, 128:BUS1 - 135:BUS8, 256:AUX1 - 263:AUX8, 512:STEREO Effect is 0:Effect 1-3:Effect 4 • In the case of PAIR, you must specify channels for which pairing is possible. • In the case of PAIR ON with COPY, you must specify Source Channel as the copy source, and Destination Channel as the copy destination. 2.12.3.25 Parameter change (Function call Event: Effect ) Reception This is received if [Parameter change RX] is ON and the [Rx CH] matches the device number included in the SUB STATUS. This is echoed if [Parameter change ECHO] is ON. When this is received, the corresponding effect's function activates (depending on the effect type). STATUS 11110000 F0 System exclusive message ID No. 01000011 43 Manufacture's ID number (YAMAHA) SUB STATUS 0001nnnn 1n n=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3E MODEL ID (digital mixer) MODEL ID 01111111 7F Universal ADDRESS 00010010 12 Function call Effect Event 0000ffff 0f function 00000000 00 0ppppppp pp Release:0, Press:1 DATA 00000000 00 0eeeeeee ee Effect number (0:Effect1 - 3:Effect4) EOX 11110111 F7 End of exclusive function Freeze Play button Freeze Record button Auto Pan 5.1 Trigger Button Auto Pan 5.1 Reset Button 0x00 0x01 0x02 0x03 channel 0:Effect1-3:Effect4 0:Effect1-3:Effect4 0:Effect1-3:Effect4 0:Effect1-3:Effect4 • This does not activate when the effect type is different. 2.12.3.26 Parameter change (Sort Table) When scene memory sort is executed on the DM1000, the memory sort table will be transmitted to Studio Manager. Studio Manager will sort the memories according to this data. If Studio Manager performs a scene memory sort, it will transmit this data to the DM1000. STATUS 11110000 F0 System exclusive message ID No. 01000011 43 Manufacture's ID number (YAMAHA) SUB STATUS 0001nnnn 1n n=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3E MODEL ID (digital mixer) MODEL ID 00001100 0C DM1000 ADDRESS 00010011 13 Library sort table 0000ffff 0f Library type DATA 0ddddddd ds Data : : 0ddddddd de Data EOX 11110111 F7 End of exclusive 8-7 conversion is performed on the data area in the same way as for bulk. 2.12.3.27 Parameter request (Sort Table) When the DM1000 receives this data, it will transmit Sort Table Data. STATUS ID No. SUB STATUS GROUP ID MODEL ID ADDRESS EOX 11110000 F0 01000011 43 0011nnnn 3n 00111110 3E 00001100 0C 00010011 13 0000ffff 0f 11110111 F7 System exclusive message Manufacture's ID number (YAMAHA) n=0-15 (Device number=MIDI Channel) MODEL ID (digital mixer) DM1000 Library sort table Library type End of exclusive 2.12.3.28 Parameter change (Key remote) Reception This is received if [Parameter change RX] is ON and the [Rx CH] matches the device number included in the SUB STATUS. This is echoed if [Parameter change ECHO] is ON. When this is received, the same processing that is executed when the key specified by Address is pressed (released). Transmission If [Parameter Change ECHO] is ON, this message is retransmitted without change. STATUS ID No. SUB STATUS GROUP ID MODEL ID ADDRESS DATA EOX 11110000 F0 01000011 43 0001nnnn 1n 00111110 3E 00001100 0C 00100000 20 0kkkkkkk kk 0kkkkkkk kk 0kkkkkkk kk 0ppppppp pp 11110111 F7 System exclusive message Manufacture's ID number (YAMAHA) n=0-15 (Device number=MIDI Channel) MODEL ID (digital mixer) DM1000 Key remote Key address H Key address M Key address L Release:0, Press:1 End of exclusive 2.12.3.29 Parameter change (Remote Meter) When transmission is enabled by receiving a Request of Remote meter, the specified meter information is transmitted every 50 msec for 10 seconds. When you want to transmit meter information continuously, a Request must be transmitted continuously within every 10 seconds. Reception This is echoed if [Parameter change ECHO] is ON. Transmission When transmission has been enabled by a Request, the parameter specified by Address will be transmitted on the [Rx CH] channel at 50 msec intervals for a duration of 10 seconds. Transmission will be disabled if the power is turned off and on again, or if the PORT setting is changed. If [Parameter Change ECHO] is ON, this message is retransmitted without change. STATUS 11110000 F0 System exclusive message ID No. 01000011 43 Manufacture's ID number (YAMAHA) SUB STATUS 0001nnnn 1n n=0-15 (Device number=MIDI Channel) GROUP ID 00111110 3E MODEL ID (digital mixer) MODEL ID 00001100 0C DM1000 ADDRESS 00100001 21 Remote meter 0mmmmmmm mm ADDRESS UL 0mmmmmmm mm ADDRESS LU 0mmmmmmm mm ADDRESS LL DATA 0ddddddd dd Data1 H 0ddddddd dd Data1 L : : EOX 11110111 F7 End of exclusive * The meter data can be either the unadjusted DECAY value of the DSP, or the table-converted value. The interpretation of the data will depend on the parameter. DM1000-Owner's Manual