2015 Polaris RZR XP 1000 EPS High Lifter Edition Owners Manual - Page 99
2015 Polaris RZR XP 1000 EPS High Lifter Edition Manual
Page 99 highlights
MAINTENANCE Cooling System Radiator Coolant Level/Changing Coolant This procedure is required only if the cooling system has been drained for maintenance and/or repair. If the overflow bottle has run dry, the level in the radiator should also be inspected. CAUTION! Escaping steam can cause burns. Never remove the pressure cap while the engine is warm or hot. Always allow the engine to cool before removing the pressure cap. 1. Remove the hood. See page 30. 2. Slowly remove the radiator pressure cap. 3. View the coolant level through the opening. 4. Use a funnel and slowly add coolant as needed. 5. Before reinstalling the pressure cap, bleed the system of trapped air. Remove the engine access panel behind the seats and use a flat-blade screwdriver to turn the bleed screw slightly, allowing the air to escape. Slowly add additional coolant to the radiator until air no longer escapes and only coolant flows from the bleed hole, then tighten the bleed screw. 6. Reinstall the pressure cap. Tip: Use of a non-standard pressure cap will not allow the recovery system to function properly. See your dealer for the correct replacement part. Overflow Bottle Pressure Cap Bleed Screw 97