Acer Altos G301 Acer Altos G301 User's Guide - Page 118

Array, Physical Drive Error Status

Page 118 highlights

106 5 Configuring IDE Software RAID Capacity Transfer Mode Part of Array Connection Model Serial Number Specifies the capacity of this physical drive. Specifies the type of transfer mode used on this physical drive. Specifies the part of the array wo which this physical drive belongs. The RAID mode for a striped array (RAID 0) is called performance, and for a mirrored array (RAID 1) is called reliability. Specifies the type of IDE connection that is used to connect this drive to the RAID controller. (primary or secondary, master or slave) Specifies the model number of the physical drive. Specifies the serial number of the physical drive. Physical Drive Error Status - This screen displays the physical drive error status. This table provides a description of each field. Field Time and Date Error Sector Description Specifies the time and date the error was logged. Specifies the error type. Specifies the sector that contains the error. Physical Drive Errors - Error codes for the physical drives display when you select the error log view. The following table provides a list and descriptions of the error codes. Code Error 01 Error 02 Error 03 Error 04 Description Media read error. The disk surface is damaged. Media write error. The disk surface is damaged. Media verify error. Missing drive type. Array To display the Array Properties, perform a Check Consistency, or rebuild the array, click the icon in the lower middle frame next to Array. After you click the icon, the Array ID displays in the right frame. The links to the Array Properties, Check Consistency, and Rebuild display as

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162

5 Configuring IDE Software RAID
106
Physical Drive Error Status
- This screen displays the physical drive
error status. This table provides a description of each field.
Physical Drive Errors
- Error codes for the physical drives display
when you select the error log view. The following table provides a list
and descriptions of the error codes.
Array
To display the Array Properties, perform a Check Consistency, or rebuild
the array, click the icon in the lower middle frame next to Array.
After you click the icon, the Array ID displays in the right frame. The
links to the Array Properties, Check Consistency, and Rebuild display as
Capacity
Specifies the capacity of this physical drive.
Transfer Mode
Specifies the type of transfer mode used on this physical drive.
Part of Array
Specifies the part of the array wo which this physical drive belongs.
The RAID mode for a striped array (RAID 0) is called
performance
,
and for a mirrored array (RAID 1) is called
reliability
.
Connection
Specifies the type of IDE connection that is used to connect this drive
to the RAID controller. (primary or secondary, master or slave)
Model
Specifies the model number of the physical drive.
Serial Number
Specifies the serial number of the physical drive.
Field
Description
Time and Date
Specifies the time and date the error was logged.
Error
Specifies the error type.
Sector
Specifies the sector that contains the error.
Code
Description
Error 01
Media read error. The disk surface is damaged.
Error 02
Media write error. The disk surface is damaged.
Error 03
Media verify error.
Error 04
Missing drive type.