Adaptec 51645 User Guide - Page 129
Environmental Specifications, DC Power Requirements, Current Requirements
UPC - 760884155622
View all Adaptec 51645 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 129 highlights
Appendix H: Technical Specifications ● 129 Environmental Specifications Note: Adaptec RAID controllers require adequate airflow to operate reliably. The recommended airflow is 200 LFM. Forced airflow is recommended. Ambient temperature with forced airflow Ambient temperature without forced airflow Ambient temperature with Battery Backup Unit (BBU) Relative humidity Altitude 0 °C to 55 ° C 0 °C to 40 ° C 0 °C to 40 ° C 10% to 90%, noncondensing Up to 3,000 meters Note: Ambient temperature measured 1" from RAID processor. DC Power Requirements Bus Type PCIe PCIe Description Ripple and noise DC Voltage Requirements 50 mV peak-to-peak (max) 3.3 V ± 9%, 12 V ± 8% Current Requirements Adaptec Model Adaptec RAID 5085 Adaptec RAID 5805 Adaptec RAID 5405 Adaptec RAID 5445 Adaptec RAID 5805Z Adaptec RAID 5405Z Adaptec RAID 5445Z Adaptec RAID 51245 Adaptec RAID 51645 Adaptec RAID 52445 Adaptec RAID 2045 Adaptec RAID 2405 Typical Current 0.45 A @ 3.3 VDC; 1.0 A @ 12.0 VDC 0.45 A @ 3.3 VDC; 1.0 A @ 12.0 VDC 0.45A @ 3.3VDC; 0.94A @ 12.0VDC 0.45A @ 3.3VDC; 1.0A @ 12.0VDC 0.39 A @ 3.3 VDC; 1.21 A @ 12.0 VDC 0.38 A @ 3.3 VDC; 1.18 A @ 12.0 VDC 0.40 A @ 3.3 VDC; 1.24 A @ 12.0 VDC 0.47A @ 3.3VDC; 1.68A @ 12.0VDC 0.47A @ 3.3VDC; 1.72A @ 12.0VDC 0.47A @ 3.3VDC; 1.78A @ 12.0VDC 0.43A @ 3.3VDC; 0.83A @ 12.0VDC 0.43A @ 3.3VDC; 0.83A @ 12.0VDC