3.3.8 Serial Console Redirection COM1(~6) Console Redirection Allows you enable or disable the console redirection feature. Configuration options: [Enabled] [Disabled] NOTE: The following item is accessible when you set Console Redirection to [Enabled]. Console Redirection Settings The settings specify how the host computer and the remote computer (which the user is using) will exchange data. Both computers should have the same or compatible settings. Terminal Type Configuration options: [VT100] [VT100Plus] [VT-UTF8] [ANSI] [VT100] ASCII char set. [VT100Plus] Extends VT100 to support color, function keys, etc. [VT-UTF8] Uses UTF8 encoding to map Unicode chars onto 1 or more bytes. [ANSI] Extended ASCII char set. Bits per second Allows you to select serial port transmission speed. The speed must be matched on the other side. Long or noisy lines may require lower speeds. Configuration options: [9600] [19200] [38400] [57600] [115200] Data Bits Configuration options: [7] [8] Parity A parity bit can be sent with the data bits to detect some transmission errors. Configuration options: [None] [Even] [Odd] [Mark] [Space] [None] Disables parity check. [Even] Parity bit is 0 if the num of 1's in the data bits is even. [Odd] Parity bit is 0 if the num of 1's in the data bits is odd. [Mark] Parity bit is always 1. [Space] Parity bit is always 0. NOTE: Mark and Space Parity do not allow for error detection. Stop Bits Stop bits indicate the end of a serial data packet. The standard setting is 1 stop bit. Communication with slow devices may require more than 1 stop bit. 3-8 N100I-EM-A

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55

3-8
N100I-EM-A
3.3.8
Serial Console Redirection
COM1(~6)
Console Redirection
Allows you enable or disable the console redirection feature.
Configuration options: [Enabled] [Disabled]
NOTE:
The following item is accessible when you set
Console Redirection
to
[Enabled]
.
Console Redirection Settings
The settings specify how the host computer and the remote computer (which
the user is using) will exchange data. Both computers should have the same or
compatible settings.
Terminal Type
Configuration options: [VT100] [VT100Plus] [VT-UTF8] [ANSI]
[VT100]
ASCII char set.
[VT100Plus]
Extends VT100 to support color, function keys, etc.
[VT-UTF8]
Uses UTF8 encoding to map Unicode chars onto 1 or more bytes.
[ANSI]
Extended ASCII char set.
Bits per second
Allows you to select serial port transmission speed. The speed must be
matched on the other side. Long or noisy lines may require lower speeds.
Configuration options: [9600] [19200] [38400] [57600] [115200]
Data Bits
Configuration options: [7] [8]
Parity
A parity bit can be sent with the data bits to detect some transmission errors.
Configuration options: [None] [Even] [Odd] [Mark] [Space]
[None]
Disables parity check.
[Even]
Parity bit is 0 if the num of 1’s in the data bits is even.
[Odd]
Parity bit is 0 if the num of 1’s in the data bits is odd.
[Mark]
Parity bit is always 1.
[Space]
Parity bit is always 0.
NOTE:
Mark and Space Parity do not allow for error detection.
Stop Bits
Stop bits indicate the end of a serial data packet. The standard setting is 1